ELECTRICAL CONNECTION
OF THE COOKER HOOD
WARNING
Place the metal box containing the electronic
components at a distance of no less than 65
cm from gas-operated cook tops or in any
case, 65 cm from the suctioning surface of
the cookerhood.
NOTA
We recommend installing the metal box con-
taining the electronic components at least 10
cm above floor level and at a suitable distan-
ce from all heat sources (e.g. oven sides or
cook top).
CAUTION
This appliance is fitted with an H05 VVF 3 con-
ductor, 0.75 mm2 (neutral, phase, and ground)
power cord.
This can be connected up to a 220 - 240 V
mono-phase electrical network through a CEI
60083 approved power socket, which must
remain accessible after installation, in com-
pliance with installation regulations.
We decline any responsibility in case of acci-
dents caused by a lack of ground connection
or incorrect ground connection. The applian-
ce must be fed through a differential protec-
tion device (RCD), with a nominal residual
current not exceeding 30mA. If the power
cord is damaged, call the after-sales service
to avoid any risk.
E-320
EN
WARNING
The downdraft connection to the electrical
network must be carried out only by profes-
sional and qualified technicians.
The downdraft must be connected to a pro-
perly installed and suitable electrical network.
The electrical system must comply with
VDE0100 standard.
DANGER
If the cooker hood presents any anomaly, di-
sconnect the appliance or remove the fuse
corresponding to the appliance power di-
sconnecting line.
If the appliance has no plug or if the plug is not
easily accessible, then a device needs to be fitted
to cut it off from the electric network; this device
must have an opening distance between contacts
on all poles of at least 3 mm.
ELECTRICAL CONNECTION
This appliance complies with the European
Directives 2006/95/EC (Low Voltage Directive)
and 2004/108/EC (Electromagnetic Compati-
bility).
While installing the appliance and carrying main-
tenance operation, make sure it is disconnected
from the electrical network or the fuses are cut out
or removed.
Check that:
• Power is enough.
• Feeder lines (mains) are in good conditions.
• The cables diameter complies with installation
regulations.
NOTA
23