9
INSTALLATION
RecIRcULATION VeRSION AIReOUTLeT
• Insert the connection extension pieces laterally
14.1 in connection 15.
• Insert the Connector 15 into the Support
bracket 7.3 and fix it with a screw.
• Make sure that the outlet of the extension
pieces 14.1 is horizontally and vertically
aligned with the chimney outlets.
• Connect the air outlet connection 15 to the
hood body outlet using either a flexible or
rigid pipe
ø 150 mm, the choice of which
is left to the installer.
• Ensure that the activated charcoal filters have
been inserted.

eLecTRIcAL cONNecTION

• Connect the hood to the mains through a
two-pole switch having a contact gap of at
least 3 mm.
• Remove the grease filters (see paragraph
Maintenance) being sure that the connector
of the feeding cable is correctly inserted in
the socket placed on the side of the fan.

cHIMNey ASSeMbLy

Upper exhaust chimney
• Slightly widen the two sides of the upper flue
and hook them behind the brackets 7.2.1,
making sure that they are well seated.
• Secure the sides to the brackets by using the
4 screws 12c (2,9 x 9,5) supplied.
• Make sure that the outlet of the extensions
pieces is aligned with the chimney outlets.
Lower exhaust chimney
• Slightly widen the two sides of the chimney
and hook them between the upper chimney
and the wall, making sure that they are well
seated.
• Fix the lower part laterally to the hood body
using the 2 screws 12c (2,9 x 9,5) supplied.
����
���
��
�����
�����
���
���
���
���
���