Xylem FLOJET FLO 5.0 Manual De Instrucciones página 6

Bomba automatica de diafragma
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 32
Operation
Figure 6.
Winterizing
CAUTION: Allowing water to freeze in the system may result in damage to the pump, plumbing system
or Exposed Industrial applications. Non-Toxic antifreeze for potable water may be used with Flojet pumps.
Follow manufacturer's recommendations. Refer to equipment manufacturer's instructions for their specific
winterizing and drainage procedures. Do not use automotive antifreeze to winterize potable water systems .
These solutions are highly toxic and may cause serious injury or death if ingested.
1. Drain the water tank. Open tank drain valve. You may use the pump to drain the tank by opening
all the valves in the system. Allow the pump to operate until the tank is empty. Do not operate
the pump more than 15 minutes continuously.
2. Open all valves and purge the water from the plumbing system. Turn off power to the pump. Be
sure that all the water from the drain lines is drained.
3. Remove quick-connect inlet and outlet fittings from the pump and turn the pump on to pump
out remaining water from the pump head. Be sure to have a catch pan or a rag under the pump to
prevent water from spilling onto the floor. Turn the pump off once the plumbing is empty. Leave
the fittings disconnected from the pump until the system is ready to be used again. Make a note
on your tank filler that the plumbing is not connected.
4. Be sure that all valves are left open to protect against damage to the plumbing.
Dimensions:
Exploded View
1
Parts List
KEY
1
2
3
4
Accessories – Snap-In Port Fittings
QUAD PORT x
1/2" MALE QEST.
We hereby declare, under our sole responsibility, that our product
to which this declaration relates has been designed to comply in
accordance with the following Directives:
Electromagnetic Compatibility Directive 2004/108/EC
Restriction of Hazardous Substances Directive (RoHS) 2011/65/EU
6
Initial Start Up
Initial Start Up
Demand Off
Demand Off
Demand On
Demand On
Width – 6 1/8 inches (155.58mm), Height – 4 3/4 inches (120.65mm),
Length – 9 7/8 inches (250.83mm)
Description
Pumphead Assembly
Pumphead Assembly
Diaphragm Kit
Motor - 12
Motor - 24
Pumpgard Strainer
20381000
20381002
QUAD PORT x
1/2" HOSE BARB
STRAIGHT
STRAIGHT
20381008
QUAD PORT x
1/2" MALE QEST.
90∞ ELBOW
2
QTY
1
1
1
1
1
1
20381006
QUAD PORT x
3/4" HOSE BARB
STRAIGHT
20381009
20381010
QUAD PORT x
QUAD PORT x
1/2" HOSE BARB
3/4" HOSE BARB
90∞ ELBOW
90∞ ELBOW
• Initial Start up
• Open all faucets
• Turn pump switch "ON"
NOTE: Expect a 10 second delay
for power up.
• When water is free of air, turn
all valves off beginning with
the valve closest to the pump
(Figure 6)
Important: Do not operate
the pump more than 15 minutes
continuously.
Kit No.
189146330A (EPDM)
189146335A (VITON)
20403040A
R2009236A
R2010180A
01740950S
20381007
QUAD PORT x
GARDEN HOSE
STRAIGHT
3

Publicidad

Tabla de contenido
loading

Tabla de contenido