Preparing The Installation; Risk Of Injury - Bosch HCP50652UC Manual De Instalación

Ocultar thumbs Ver también para HCP50652UC:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Preparing the installation

1. Mark a vertical center line on the wall from the ceiling
to the lower edge of the extractor hood.
2. Align the drill template on the center line and the
bottom edge of the extractor hood and glue on.
3. Mark positions for the screws and the contour of the
attachment area.
4. Mark holes for the flue's angle brackets. The center of
the angle bracket is marked with a hole. Place the
angle brackets in the center of the center line, align
them horizontally and mark the positions of the holes.
A Ceiling
B Wall
C Centerline
Fitting the wall retainer
1. Drill holes with Ø 5/16" (7.9 mm) for the angle bracket.
2. Press in the wall plugs flush with the wall.
3. Screw screws (5x34 mm) into the wall plugs by hand
in order to spread the plugs apart.
4. Unscrew screws.
5. Screw on the angle bracket for the flue duct.
Making the ceiling breakthrough
1. Using a spirit level, extend the center line of the drill
template to the ceiling.
2. Mark the ceiling breakthrough (Ø 8 1/2" (216 mm)) at
least 4 5/8" (117 mm) away from the wall.
Making the wall breakthrough
1. Using a spirit level, extend the center line of the drill
template to the ceiling.
2. Depending on the curved section of the wall
breakthrough (Ø 8 1/2" (216 mm)) mark at least
26 1/2" (660 mm) above the bottom edge of the
extractor hood.
A
B
C
Mounting the back-pressure flap
1. Using 4 screws (4.2 x 8 mm), attach the air transition
spacer to the hood.
2. Using 4 screws (4.2 x 8 mm), attach the back-pressure
flap and the air transition spacer.
A Transition Spacer
B Air Transition
Mounting the extractor hood on the wall
WARNING

RISK OF INJURY

The appliance is heavy. To move the appliance, 2 people
are required. Use only suitable tools and equipment.
1. Initially remove the protective foil from the back of the
appliance and, following installation, remove foil
completely.
2. Mark the upper holes on the wall.
Note: Ensure that the holes are horizontal and aligned
centered on the center line.
3. Drill the upper holes. Adhere to a distance of 1/4"
(6 mm) between the wall and screw head.
4. Remove grease filters.
5. Hang the extractor hood on the upper screws on the
wall.
6. Mark holes for the lower holes.
7. Remove the extractor hood from the wall.
8. Drill the lower holes.
9. Hang the extractor hood on the upper screws on the
wall.
B
A
Page 9

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Hcp56652uc

Tabla de contenido