Sime AQUA Serie Manual Del Usuario página 78

Ocultar thumbs Ver también para AQUA Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

steps shown in fig. 13.
4.5
DISASSEMBLY
OF EXPANSION VESSEL
The heating expansion tank is disas-
sembled in the following manner:
– Make sure that the boiler has been
emptied of water.
– Unscrew the union which connects
the expansion tank.
– Remove the expansion tank.
Before filling up the system make sure
that the expansion tank is reloaded at
the pressure of 0.8 ÷ 1 bar.
4.6
BURNER MAINTENANCE
(figg. 14 - 14/a - 14/b)
To dismantle the burner from the
boiler door, remove the nut (fig. 14).
– To access the internal part of the
burner, remove the air lock unit
held in place by two screws to the
sides and remove the right hand
shell, which is held in place by four
screws, taking care not to damage
the O-ring seal. OR.
– To dismantle the nozzle holder and
heater unit, proceed as follows:
– open the cover, which is held in
place by a screw, and remove the
heater cables (1 fig. 14/a) pro-
tected by a heat resistant sheath;
remove the fairlead and pass the
cables through the hole.
– remove the two cables from the
ignition electrodes fastened in
place with a faston.
– loosen the union (2 fig. 14/a) and
remove the four screws which
fasten the collar (3 fig. 14/a) to the
burner.
– To dismantle the eater or thermo-
stat, refer to figure 14/b.
4.7
CLEANING
AND MAINTENANCE
Preventive maintenance and check-
ing of the efficient operation of the
equipment and safety devices must be
carried out at the end of each heating
season exclusively by the authorised
technical staff.
4.7.1
Cleaning smoke
ducts (fig. 15)
Use an adequate swab for cleaning the
78
1
2
1
2
3
KEY
1 Control bow cables
2 Connection
3 Collar
KEY
1 Heater stat
2 Cap
3 Heater
3
RONDO' 3/4 OF
ESTELLE 3/4 OF
RONDO' 5/6 OF
ESTELLE 5/6 OF
Fig. 14
Fig. 14/a
Fig. 14/b
Fig. 15

Publicidad

Tabla de contenido
loading

Tabla de contenido