Pump high efficiency diagnose and remedy (fig. 11/a)
LED diagnose and remedy
Led color
Continuous green
Red/green blinking
Red blinking
No LED
4

USE AND MAINTENANCE

4.1
TANK MAINTENANCE
The preparation of hot treated water
is guaranteed by a heater in INOX
AISI 316L, complete with magnesi-
um anode for protecting the heater
76
Meaning
Diagnostic
Normal running
Pump run as
expected or is faced
to a phenomenon
that shortly affects
its running
Abnormal situation
Pump will restart
(pump functional
by itself after the
but stopped)
abnormal situation
disappeared
Stopped (e.g. pump
Reset the pump
blocked)
Check LED signal
No power supply
No voltage
on electronics
and inspection flange for control and
cleaning.
The magnesium anode (20 fig. 2 -
16 fig. 2/a) should be periodically
controlled and substituted whenever
worn out.
Signal LED
Cause
Remedy
Normal operation
1. Undervoltage or
1. Check voltage supply:
Overvoltage:
U<160V or U> 253V
2. Module overvoltage:
2. Check water & ambient
T° inside motor too high
Pump cannot restart
Change pump
itself due to a permanent
failure
1) Pump is not connected
1) Check cable connection
to power supply
2) LED is damaged
2) Check if pump is runnning
3) Electronics are damaged
3) Change pump
4.4
The shell can be completely disas-
sembled for an easy maintenance of
the boiler by following the numeric
195V<U<253V
Fig. 11/a
DISASSEMBLY
OF OUTER CASING (fig. 13)