4.12.2 RETURN TO SERVICE
Refer back to the appropriate safety warnings.
To return the unit to service after storage, proceed as follows:
1.
Verify that utility power is turned off and that the AUTO/OFF/
MANUAL switch is set to OFF.
2.
Check the tag on the engine for oil viscosity and classification.
Verify that the correct recommended oil is used in the engine
(see the Engine Oil Recommendations section). If necessary,
drain and refill with the proper oil.
3.
Check the state of the battery. Fill all cells of unsealed bat-
teries to the proper level with distilled water. DO NOT USE
TAP WATER IN THE BATTERY. Recharge the battery to 100
percent state of charge, or, if defective, replace the battery.
See "Specifications," for type and size.
4.
Clean and wipe the entire generator.
5.
Make sure the 7.5A fuse is removed from the generator con-
trol panel. Reconnect the battery. Observe battery polarity.
Damage may occur if the battery is connected incorrectly.
6.
Open the fuel shutoff valve.
7.
Insert the 7.5A fuse into the generator control panel. Start the
unit by moving the AUTO/OFF/MANUAL switch to MANUAL.
Allow the unit to warm up thoroughly.
8.
Stop the unit by setting the AUTO/OFF/MANUAL switch to OFF.
9.
Turn on the utility power to the transfer switch.
10. Set the AUTO/OFF/MANUAL switch to AUTO.
11. The generator is now ready for service.
If the battery was dead or disconnected, the exercise timer, cur-
rent date and time must be reset.
NOTE:
4.12.3 MAINTENANCE / ACCESSORY ITEMS
The manufacturer provides all the proper OEM maintenance parts
needed to properly maintain and service your generator along with
accessory type items that provide enhanced performance. We
encourage you to visit us at www.honeywellgenerators.com to
locate a local authorized service provider that can provide you with
these itmes, or you may choose to order directly off the Generator
Accessory Tab on the site.
Not all items listed are available for sale at www.honeywellgen-
erators.com.
Scheduled Maintenance Kits with Oil
Part Number
Description
0J576600SM
Kit for 10kW Generator
0J57660SSM
Kit for 10kW Generator
0J576700SM
Kit for 15kW Generator
0J57570SSM
Kit for 15kW Generator
0J576800SM
Kit for 20kW Generator
0J57680SSM
Kit for 20kW Generator
Cold Weather Kits
0J580000CW
Cold Weather Kit 10-20kW
Touch-up Paint
0J579700TP
Kit Paint Medium Grey
Fascia Skirt Wrap
Remote Monitor System
Auxiliary Transfer Switch Lockout
GenPad
Maintenance
NOTE:
Oil Type
10W-30
5W-30 synthetic
10W-30
5W-30 synthetic
10W-30
5W-30 synthetic