SPECIAL SYMBOLS

In addition to the battery service life which is accessible when ON is pressed when
switching on, the clamp can display the battery level at any time:
For an alkaline battery if the service life is less than 25 %: the
symbol flashes,
indicating that around 50 resistance measurements can be made with guaranteed
values. If it is less than 20 %: the
symbol is continuously displayed, measure-
ments are only indicative, they can not be recorded in the memory.
When the battery is flat, the instrument switches off automatically.
NOISE
This symbol appears when a disturbing current which is too great circulates in the earth
conductor, i.e. when the product U = R
(I
I
) is greater than approximately
loop
disturb. +
meas.
40 V. Resistance measurement is not then guaranteed.
This symbol appears when the clamp is open or incorrectly closed. It may be displayed
on the screen when the jaw faces are not perfectly clean.
The clamp can not make a measurement in this case.
R < .1Ω Ω Ω Ω Ω
This symbol appears when the resistance measured is less than 0.1 Ω
OL
This appears on the digital display when the measured value exceeds the measurement
range (1200 Ω in resistance measurement on all models, 30 A in current measurement
on the C.A 6412 and C.A 6415 accompanied with an intermittent beep).
38

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

C.a 6412C.a 6415C.a 6415r

Tabla de contenido