Locate the two low voltage wires near the main pipe and attach them to the control panel
on the power unit using the provided crimp-on terminals. Be certain you comply with your lo-
cal electrical codes and regulations. Plug the unit into the electrical outlet. You are now ready
to check the installation of the unit:
• Plug the hose into each inlet valve to be sure the electrical contacts operate properly.
• Check each inlet valve for air leaks
• Check each pipe connection for air leaks.
• Be sure the dirt receptacle is properly secured to the power unit.
• Be sure the filter is properly installed in the power unit.
Your cleaning system is ready to use.

HOW TO USE

The Electrolux Vacuum System is designed to provide the utmost in dust-free, quiet
cleaning. The power unit, which is mounted in a remote area of your home, is connected to
centrally located inlet valves with a system of lightweight plastic pipes. Using the cleaner is as
simple as inserting the vacuum hose into an inlet valve after attaching the appropriate tool.
Overload-Protection Reset
The Electrolux vacuum system features an overload protection device, which can be reset
should the motor be overloaded causing the circuit to open. Should this happen and the
power unit fails to operate, either:
1) Unplug the power unit from the electrical outlet for 30
seconds and then plug the unit back in, or
2) Depress the reset button located on the side of the power
unit. (LCD Models Only)
If the protector continues to trip, contact the authorized
service center nearest you.
Inlet Valves
Each inlet valve has electrical contacts which activate the power unit motor when the
hose is connected and in use. The system shuts off as soon as the hose is removed or
turned off.
An obstruction in the inlet valve may cause the power unit to continue to run after the
hose is removed from the inlet. Check all the inlet valves and remove any obstruction to shut
down the power unit.
When unplugging the hose from the inlet valve, hold the inlet cover open for a few seconds
to allow the suction to decrease and protect the inner seal.

HOW TO MAINTAIN

The instructions given in the booklet serve as a guide to routine maintenance. Proper
airflow or suction can be maintained by keeping the dirt receptacle and filter clean and the
plastic pipe and hose free from clogs. Check the Home Maintenance Guide at the end of this
booklet for suggestions before calling for service.
Dirt Receptacle and Filter
Reduced airflow or suction indicates the built-in vacuum system is not operating at maximum
efficiency: If the dirt receptacle is full and the filter is clogged, no air can pass through the unit