When ventilating the room Stop the heating by setting the switch to the Arrêt position.
If you live for less than 24
hours
If you live for more than 24
hours or during summer
Problem
The device does not heat
The heating device
heats constantly
The last elements top and
bottom are cooler than the
rest of the device
The device's surface is very
hot.
The fan stops prematurely
R
ECOMMENDATIONS OF USE
Lower the temperature.
Set the temperature wheel A to
I
N CASE OF PROBLEM
- Check that the premise circuit breakers are triggered or that the shed-
der (if you have one) has not interrupted the device's power supply.
- Check the air temperature in the room.
- Switch the heating off, then back on (C switch):
• If the heating indicator B blinks : the measurement probe is damaged.
Call your electrician to ensure its replacement.
- Check that the device is not located in a draft or that the temperature
setting has not been altered.
- At the top, the upper elements are not completely filled to allow for
expansion of the thermodynamic fluid. They heat up only by conduc-
tion.
- At the bottom, the elements convey the fluid return, which has trans-
mitted its heat.
It is normal for the device to be hot when it is operating. The maximum
surface temperature is restricted in accordance with the NF Electricité
Performance standard. However, if you think that your device is always
too hot, check that the output is suitable for the area of your room (we
recommend 100W / m
which would disrupt its setting.
- Check that the air inlet grills are not blocked. Proceed to clean them
if necessary (refer to the Maintenance paragraph).
- Check that the room temperature has not reached too high a level. In
this case, fan stoppage is normal. Just wait for the ambient temperature
to drop before reusing the Turbo mode.
- If you live at an altitude of more than 1000m, because the air is less
dense this may cause the item to rise in temperature more quickly.
This may therefore become a repetitive problem (without having any
major effect on the service life of the machine's components).
In all cases, follow the procedure below to restart the machine:
• Switch off the heating (switch C).
• Wait at least 10 minutes
• Restart the heating (switch C).
.
Check
2
) and that the device is not placed in a draught,
18