10. Technical data
CA BASIC 2000
Airflow
Weight of the blower unit incl. the
filter and battery
Noisiness
NiMh battery lifetime
One charging cycle
Belt size
Recommended temperature range
Recommended humidity range
Certification
Expected operating time of the blower unit
after being fully charged (hours)
CA BASIC DUAL FLOW
CA BASIC FLOW CONTROL
CA CHEMICAL
Airflow
Weight of the blower unit incl. the
filter and battery
Noisiness
NiMh battery lifetime
One charging cycle
Belt size
Recommended temperature range
Recommended humidity range
Certification
Expected operating time of the
blower unit after being fully charged
(hours)
CA CHEMICAL DUAL FLOW
Notified body for CE testing:
CAB DUAL FLOW
160* - 140 l/min
200* - 180 l/min
* with fully charged attery and clean filters
EN 12 941/A2 TH1
Airflow
min
middle
X
X
X
CACH DUAL FLOW
140* a 200* l/min
* with fully charged attery and clean filters
1 050 g
55 to 61 dB
500 to 700 charging cycles
10 to 14 hours
80 to 100 cm
10°to 40°C
20 to 80 % Rh
EN 12 941 TH1
EN 12 942 TM3
Airflow
Mode mask
Mode hood
Eco
min
max
(min)
X
X
X
NOTE! operating time can be shortened in case of clogged filter undercharged battery
Occupational Safety research Institute v.v.i.
Testing lab. 1024
Jeruzalémská 9, 116 52 Praha 1
Authorized body 235
Notified body 1024
900 g
55 - 61 dB
500 to 700 charging cycles
10 to 14 hours
80 to 100 cm
10°to 40°C
20 to 80 % Rh
Filter
max
P R SL
NOTE! operating time can be
shortened in case of clogged filter
11-12 h
X
6 h
10 h
6-7 h
X
4-5 h
Filter
gas
particle
P R SL
A2
Turbo
(max)
7,0 h
X
4,0 h
16 – 17 h
8 – 8,5 h
X
7,5 – 8 h
8
CAB FLOW CONTROL
140 to 210 l/min
(at 8 adjustable flow rates)
EN 12 941/A2 TH2/TH3
or undercharged battery
combined
ABEK2P R SL
7,5 h
7,0 – 7,5 h
4,5 h
4,0 – 4,5 h
16 – 17 h
16 – 17 h
8 – 8,5 h
8 – 8,5 h
7,5 – 8 h
7,5 – 8 h