Guía rápida
1.5 Resumen de parámetros
0-** Operation/Display
0-0* Basic Settings
0-03 Regional Settings
*[0] International
[1] US
0-04 Oper. State at Power-up
(Hand)
[0] Resume
*[1] Forced stop, ref=old
[2] Forced stop, ref=0
0-1* Set-up Handling
0-10 Active Set-up
*[1] Setup 1
[2] Setup 2
[9] Multi Setup
0-11 Edit Set-up
*[1] Setup 1
[2] Setup 2
[9] Active Setup
0-12 Link Setups
[0] Not Linked
*[20] Linked
0-31 Custom Readout Min Scale
0,00 – 9999,00 * 0,00
0-32 Custom Readout Max Scale
0,00-9999,00 * 100,0
0-4* LCP Keypad
0-40 [Hand on] Key on LCP
[0] Disabled
*[1] Enabled
0-41 [Off / Reset] Key on LCP
[0] Disable All
*[1] Enable All
[2] Enable Reset Only
0-42 [Auto on] Key on LCP
[0] Disabled
*[1] Enabled
0-5* Copy/Save
0-50 LCP Copy
*[0] No copy
[1] All to LCP
[2] All from LCP
[3] Size indep. from LCP
0-51 Set-up Copy
*[0] No copy
[1] Copy from setup 1
[2] Copy from setup 2
[9] Copy from Factory setup
0-6* Password
0-60 (Main) Menu Password
0-999 *0
0-61 Access to Main/Quick Menu
w/o Password
*[0] Full access
[1] LCP:Read Only
[2] LCP:No Access
1-** Load/Motor
1-0* General Settings
1-00 Configuration Mode
*[0] Speed open loop
[3] Process
1-01 Motor Control Principle
[0] U/f
*[1] VVC+
1-03 Torque Characteristics
*[0] Constant torque
[2] Automatic Energy Optim.
1)
Solo M4 y M5
MG02B905
Guía rápida
Resumen de parámetros
1-05 Local Mode Configuration
[0] Speed Open Loop
*[2] Consulte la configuración en
par. 1-00
1-2* Motor Data
1-20 Motor Power [kW] [HP]
[1] 0,09 kW / 0,12 CV
[2] 0,12 kW / 0,16 CV
[3] 0,18 kW / 0,25 CV
[4] 0,25 kW / 0,33 CV
[5] 0,37 kW / 0,50 CV
[6] 0,55 kW / 0,75 CV
[7] 0,75 kW / 1,00 CV
[8] 1,10 kW / 1,50 CV
[9] 1,50 kW / 2,00 CV
[10] 2,20 kW / 3,00 CV
[11] 3,00 kW / 4,00 CV
[12] 3,70 kW / 5,00 CV
[13] 4,00 kW / 5,40 CV
[14] 5,50 kW / 7,50 CV
[15] 7,50 kW / 10,00 CV
[16] 11,00 kW / 15,00 CV
[17] 15,00 kW / 20,00 CV
[18] 18,50 kW / 25,00 CV
[19] 22,00 kW / 29,50 CV
[20] 30,00 kW / 40,00 CV
1-22 Motor Voltage
50-999 V *230-400 V
1-23 Motor Frequency
20-400 Hz *50 Hz
1-24 Motor Current
0,01-100,00 A *Dep. tipo motor
1-25 Motor Nominal Speed
100-9999 r/min * Dep. tipo motor
1-29 Automatic Motor Tuning
(AMT)
*[0] Off
[2] Enable AMT
[3] Complete AMT with Rotating
motor
1-3* Adv. Motor Data
1-30 Stator Resistance (Rs)
[Ω] * Dep. de datos del motor
1-33 Stator Leakage Reactance
(X1)
[Ω] * Dep. de datos del motor
1-35 Main Reactance (Xh)
[Ω] * Dep. de datos del motor
1-5* Load Indep. Setting
1-50 Motor Magnetisation at 0
Speed
0-300 % *100 %
1-52 Min Speed Norm. Magnet.
[Hz]
0,0-10,0 Hz *0,0 Hz
1-55 U/f Characteristic - U
0-999,9 V
1-56 U/f Characteristic - F
0-400 Hz
1-6* Load Depen. Setting
1-60 Low Speed Load Compen-
sation
0-199 % *100 %
1-61 High Speed Load Compen-
sation
0-199 % *100 %
1-62 Slip Compensation
-400-399 % *100 %
Danfoss A/S © Rev. 2014-02-27 Reservados todos los derechos.
1-63 Slip Compensation Time
Constant
0,05-5,00 s *0,10 s
1-7* Start Adjustments
1-71 Start Delay
0,0-10,0 s *0 0 s
1-72 Start Function
[0] DC hold/delay time
[1] DC brake/delay time
*[2] Coast/delay time
1-73 Flying Start
*[0] Disabled
[1] Enabled
1-8* Stop Adjustments
1-80 Function at Stop
*[0] Coast
[1] DC hold
1-82 Min Speed for Funct. at Stop
[Hz]
0,0-20,0 Hz *0,0 Hz
1-9*Motor Temperature
1-90 Motor Thermal Protection
*[0] No protection
[1] Termistor warning
[2] Thermistor trip
[3] Etr warning
[4] Etr trip
1-93 Thermistor Resource
*[0] None
[1] Analog input 53
[6] Digital input 29
2-** Brakes
2-0* DC-Brake
2-00 DC Hold Current
0-150 % *50 %
2-01 DC Brake Current
0-150 % *50 %
2-02 DC Braking Time
0,0-60,0 s *10,0 s
2-04 DC Brake Cut In Speed
0,0-400,0 Hz *0,0 Hz
2-1* Brake Energy Funct.
2-10 Brake Function
*[0] Off
[1] Resistor brake
[2] AC brake
2-11 Brake Resistor (ohm)
Mín. / máx. / predeterminada: dep.
potencia
2-14 Brake Voltage reduce
0 - Dep. potencia* 0
2-16 AC Brake, Max current
0-150 % *100 %
2-17 Overvoltage Control
*[0] Disabled
[1] Enabled (not at stop)
[2] Enabled
2-2* Mechanical Brake
2-20 Release Brake Current
0,00-100,0 A *0,00 A
2-22 Activate Brake Speed [Hz]
0,0-400,0 Hz *0,0 Hz
3-** Reference / Ramps
3-0* Reference Limits
3-00 Reference Range
*[0] Min - Max
[1] -Max - +Max
3-02 Minimum Reference
–4999-4999 *0,000
3-03 Maximum Reference
–4999-4999 *50,00
3-1* References
3-10 Preset Reference
–100,0-100,0 % *0,00 %
3-11 Jog Speed [Hz]
0,0-400,0 Hz *5,0 Hz
3-12 Catch up/slow Down Value
0,00-100,0 % * 0,00 %
3-14 Preset Relative Reference
-100,0-100,0 % *0,00 %
3-15 Reference Resource 1
[0] No function
*[1] Analog Input 53
[2] Analog input 60
[8] Pulse input 33
[11] Local bus ref
[21] LCP Potentiometer
3-16 Reference Resource 2
[0] No function
[1] Analog in 53
*[2] Analog in 60
[8] Pulse input 33
*[11] Local bus reference
[21] LCP Potentiometer
3-17 Reference Resource 3
[0] No function
[1] Analog Input 53
[2] Analog input 60
[8] Pulse input 33
*[11] Local bus ref
[21] LCP Potentiometer
3-18 Relative Scaling Ref.
Resource
*[0] No function
[1] Analog Input 53
[2] Analog input 60
[8] Pulse input 33
[11] Local bus ref
[21] LCP Potentiometer
3-4* Ramp 1
3-40 Ramp 1 Type
*[0] Linear
[2] Sine2 ramp
3-41 Ramp 1 Ramp up Time
1)
0,05-3600 s *3,00 s (10,00 s
)
3-42 Ramp 1 Ramp Down Time
0,05-3600 s *3,00 s (10,00 s
1)
)
3-5* Ramp 2
3-50 Ramp 2 Type
*[0] Linear
[2] Sine2 ramp
3-51 Ramp 2 Ramp up Time
0,05-3600 s *3,00 s (10,00 s
1)
)
3-52 Ramp 2 Ramp down Time
1)
0,05-3600 s *3,00 s (10,00 s
)
3-8* Other Ramps
3-80 Jog Ramp Time
1)
0,05-3600 s *3,00 s (10,00 s
)
3-81 Quick Stop Ramp Time
1)
0,05-3600 s *3,00 s (10,00 s
)
11