Accumulated Time Indication
The time indication accumulates time in hours and minutes
when the WRT-860A is on. Press the SET/DISPLAY
button to switch the channel indication to the time-of-use
indication.
ATT
Error Messages
When a problem occurs, one of the following error
messages may appear on the display.
Messages
Error 1
An error occurred in backup memory data.
Error 2
The PLL synthesized circuit is in trouble.
Error 3
The battery voltage exceeds the allowable value.
CH
Contents
To reset the time indication
Reset the indication to "0:00" whenever you replace the
batteries so that it can display the running time of the
batteries.
1 Set the POWER switch to ON (transmit mode).
2 Press the SET/DISPLAY button and go to the time-of-
use indication.
3 Press and hold the SET/DISPLAY button down for at
least 1 second until the indicator starts flashing.
4 Press the – button.
The time indication resets to "0:00."
Measures
The data was initialized. Set the transmitting channel and
the input attenuation again.
Contact your Sony dealer.
Use the specified batteries.
17