Nidec Unidrive M400 Guía Detallada Del Usuario página 11

Ocultar thumbs Ver también para Unidrive M400:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

STEP 12: Understand key parameters and restoring default
When changing a parameter, the new value is saved when pressing the Enter button to return to parameter view
mode from parameter edit mode.
Restoring default parameters:
1.
Ensure the drive is not enabled, i.e. terminal 31 and 35 are open.
2.
Select 'Reset 50 Hz Defs' (50 Hz settings) or 'Reset 60 Hz Defs' (60 Hz settings) in Pr 00.000
3.
Press the red reset button
Parameter
00.001 Minimum Speed
00.002 Maximum Speed
00.003 Acceleration Rate 1
00.004 Deceleration Rate 1
00.005 Drive Configuration
00.006 Motor Rated Current
00.007 Motor Rated Speed
00.008 Motor Rated Voltage
00.009 Motor Rated Power Factor
00.010 User Security Status
Unidrive M400 Step By Step Guide
Issue Number: 2
Range ( )
0.00 to Pr 00.002 Hz
0.00 to 550.00 Hz
0.0 to 32000.0 s/100 Hz
0.0 to 32000.0 s/100 Hz
Refer to the Control Quick Start Guide
for further information on all drive configurations
0.00 to Drive Rating Amps
0.0 to 33000.0 rpm
0 to 765 V
0.00 to 1.00
Refer to the Control Quick Start Guide
for further information
Default ( )
0.00 Hz
Def.50: 50.00 Hz
Def.60: 60.00 Hz
5.0 s/100 Hz
10.0 s/100 Hz
AV
Maximum Heavy Duty
Rating Amps
Def.50: 1500.0 rpm
Def.60: 1800.0 rpm
200 V drive: 230 V
400 V drive Def.50: 400 V
400 V drive Def.60: 460 V
575 V drive: 575 V
690 V drive: 690 V
0.85
Level 1
11