RFID Errors
See the RFID Application Notes for more information. Check with your System
Administrator about the format. The printer does not recalibrate (feed a blank
label) after an RFID error.
Error
Description/Action
052
Data type in the RFID Data Field is invalid.
053
The starting block in the RFID Data Field is invalid.
226
Rule Record Line xx. Upload device is invalid.
228
Memory class identifier is invalid.
229
Byte code is invalid.
230
Lock code is invalid.
715
Invalid data length/data mismatch in the RFID Data Field. This
error also occurs when there is an error in the Expanded
C1Gen2 fields.
732
RFID Hardware Error. A non-RFID printer received a format
containing an RFID Data Field.
740
Command, hardware, or memory allocation error.
741
RFID tag missing - not found in the area inside the printer where
the RFID tag is programmed. Check supply loading. Make sure
the RFID tag was not moved out of the programmable range.
742
Tag erase failed. The RFID tag was found in the RF Field, but
could not be erased.
743
Program tag failed. The RFID tag was found in the RF Field, but
could not be programmed.
744
Tag locked fail. The RFID tag is unable to be programmed
because it is already locked.
746
Lock tag fail. The RFID tag has not been locked to prevent
reprogramming.
747
Time out failure. An RFID command (read, program, etc.) has
failed to complete in the maximum amount of allowed time.
748
Invalid data length/data mismatch from RFID interrogator
module.
749
RFID Verify Fail. The RFID verification process failed after
writing (programming) tag.