Page 18
LYNX 06
Guide for the installer
Display
Param-
Value
eter
Hea ting function: If you activate this function, the control unit feeds the
motor at a very low voltage in order to maintain the motor at a temper-
ature above ambient temperature. This function is active only when
the automated system is closed at rest, and if an OPEN command is
sent, the function is interrupted.
0
Function disabled
1
Function enabled – a heating cycle every 5 minutes
M
2
Function enabled – a heating cycle every 10 minutes
3
Function enabled – a heating cycle every 15 minutes
4
Function enabled – a heating cycle every 20 minutes
Imm ediate closure: This function is active only when the function can
only be activated combined with function logics with Automatic re-
closure, Automatic, Step-by-step automatic or Condo, and with the
safety devices active only in closure "y0". With this function activat-
ed, and while the automated system is open in pause mode, when a
change in the state of the safety devices' is detected, e.g. when tran-
siting in front of the photocells, the automated system closes imme-
diately without waiting for the pause time to elapse.
0
Immediate closure disabled
o
1
Immediate closure activated, but only with "y0"
Imm ediate closure / Timer: This function enables you to
activate immediate closure or automation shut-down with
the OPEN/CLOSE command. The function can be activated
only when combined with function logics with automatic
re-closure, Automatic logic, Automatic step-by-step logic, or Condo.
Imm ediate closure activated: with the automated sys-
tem open in pause mode, an impulse of the OPEN/
0
CLOSE command causes the automated system
to close immediately without waiting for the pause
time to elapse.
Tim er function activated: If you activate this function,
P
with the automated system open in pause state, at
every OPEN/CLOSE command, the control unit re-
starts the pause time count. If the command is main-
1
tained active, the control unit stops the pause time
count and the automated system remains idle. The
control unit resumes the pause time count only when
the OPEN/CLOSE command is released.
Sof t start: This function enables a softer start of the automated system.
0
Soft start function disabled
r
1
Soft start function enabled
Ope r a t i o n o f s a f e t y d e v i c e s : T h i s p a r a m e t e r e n a b l e s
you to select the intervention method of the safety devices
connected to the control unit.
Safety devices active only during closure of the auto-
0
mated system
y
Safety devices active during the closure and opening of
1
the automated system
Ass istance request: This function allows you to set the number of cy-
cles to be run before maintenance begins. For information about the
operation of this function, see the next paragraph.
0
Assistance request disabled
1
Assistance request after 10,000 cycles
2
Assistance request after 20,000 cycles
3
Assistance request after 30,000 cycles
4
Assistance request after 40,000 cycles
U
5
Assistance request after 50,000 cycles
6
Assistance request after 60,000 cycles
7
Assistance request after 70,000 cycles
8
Assistance request after 80,000 cycles
9
Assistance request after 90,000 cycles
Cyc le counter: The number of cycles, in thousands, performed by the
automated system is displayed. For example, if "15" is shown, this
means that the automated system has performed 15,000 cycles. For
more detailed information, see the next paragraph.
Indicates the number of cycles performed by the auto-
00
mated system
The indicated conditions are the control unit's default. Make a
note of the adjustments carried out in order to restore them if the
Description
control unit is replaced.
You can access and modify the operation parameters only when
the automated system is closed in rest position - the display must
indicate value "– –".
Whenever you access display / modification of the operating
parameters, at the next OPEN impulse, the control unit runs
a programming procedure, recalculating the opening and
closing time. The automated system does not perform the
slow-downs during the first opening.
10.1. ASSISTANCE REQUEST
This function allows you to set the number of cycles to be run before
a technical assistance job. When the number of set cycles is reached,
this is signalled by about 5 seconds flashing, at the end of every closure
manoeuvre and the control unit's display indicates value "AS". The
resetting of the number of cycles must be done manually.
This function signals but does not prevent normal operation of the
automated system.
The screen after parameter "U" shows the number of cycles in thousands,
e.g., if you read "05"this means that the automated system has performed
5,000 cycles. The maximum number of cycles the control unit can count
is 99,000 - when this value is reached, the count stops and must be
manually reset.
10.1.1. r
esetting the nuMber oF cycles
This is the procedure for resetting the number of cycles:
1. Press and hold down push-button P1 until the first parameter "A"
appears on the display.
2. Scroll all the operating parameters until the number of performed
cycles is shown.
3. Simultaneously press push-buttons P1 and P2 for about 10
seconds.
4. When value "00" appears on the display, cancellation has been
done.
5. Press key P1 again, and wait for 60 seconds, to return to normal
operation.
6. Give an OPEN impulse to perform a cycle.
11. START-UP
Follow the procedure below to start up the system for the first time:
1. Power up the automated system and check that all the LEDs are in
the situation described in paragraph 8.
2. Make sure that the display shows value "– –".
3. Adjust the operating parameters, as described in paragraph 10.
4. When you have finished adjusting the parameters, give an OPEN/
CLOSE impulse, using any impulse generator connected to this
input, or the radio control if already memory-stored.
5. The control unit starts an OPENING manoeuvre, until the opening
travel limit device is reached and the display shows value "OP".
During this stage, the control unit does not perform any slow-
down.
If the automated system does not move and the display shows
value "OP", this means that it is performing a closing
manoeuvre and the motor wires must be reversed. Give a
RESET command by pressing push-button P5, cut power
and reverse the wires connected to terminals 6 & 8. Restore
the power supply and resume from point 4.
6. When the opening travel limit device has been reached, providing
automatic re-closing has been enabled, the control unit starts
counting the pause time and the display shows value "tc". If automatic
re-closure was not activated, the automated system remains idle
waiting for a new OPEN/CLOSE impulse, and the display shows
value "OP".
7. When the set pause time has elapsed, with automatic re-closure,
or at the next OPEN/CLOSE impulse, without automatic re-closure,
the automated system starts the closing manoeuvre until the closing
travel limit device is reached. The display shows value "CL".
8. During the closing manoeuvre, the control unit performs the set
slow-down.
9. When the closing stage has finished, the display shows value "– –"
and the automated system is ready for normal operation.
If the described procedure begins with the automated system
half open or fully open, e.g. following a RESET command, the
control unit does not perform slow-down either during the closing
manoeuvre. Command another cycle and check if the automated