scription of the configuration dip switch.
scription of the configuration dip switch.
The SW1 configuration dip switch is located in the upper
The SW1 configuration dip switch is located in the upper
right part of the module.
right part of the module.
The operation mode of the converter is defined according to the dip switch 2 and 3
The operation mode of the converter is defined according to the dip switch 2 and 3
combinations:
combinations:
Column encoder (Master):
Column encoder (Master):
Activate this mode if you have PLUS door panels before the converter and
Activate this mode if you have PLUS door panels before the converter and
VISTA PLUS monitors (without door panel) after the converter (see page
VISTA PLUS monitors (without door panel) after the converter (see page
26).
26).
Column encoder (Slave):
Column encoder (Slave):
Activate this mode if you have PLUS door panels before the converter and
Activate this mode if you have PLUS door panels before the converter and
VISTA PLUS monitors and door panels after the converter. (See page 26).
VISTA PLUS monitors and door panels after the converter. (See page 26).
Exchange interface:
Exchange interface:
Activate this mode if placing a PLUS porter's exchange in a VISTA PLUS
Activate this mode if placing a PLUS porter's exchange in a VISTA PLUS
installation (see page 25).
installation (see page 25).
D
D
e
e
scription of the configuration jumpers.
scription of the configuration jumpers.
JP1
JP1
Auto
Auto
Off
Off
JP2
JP2
On
On
Off
Off
JP4
JP4
On
On
Off
Off
* Factory default
* Factory default
Loads the VISTA PLUS installation with a
Loads the VISTA PLUS installation with a
communications resistor.
communications resistor.
Set to ON position only if you do not have
Set to ON position only if you do not have
the VISTA PLUS door panel in the
the VISTA PLUS door panel in the
installation.
installation.
Set to ON to program the column.
Set to ON to program the column.
This function should only be used if the module is being used as
This function should only be used if the module is being used as
column encoder (see page 26).
column encoder (see page 26).
Once the programming progress is finished return the switch to
Once the programming progress is finished return the switch to
OFF position.
OFF position.
The programming steps are described on page 29.
The programming steps are described on page 29.
End of line resistor (Only in porter´s exchange interface mode).
End of line resistor (Only in porter´s exchange interface mode).
Set to AUTO if the porter's exchange is connected through a D4L-R5
Set to AUTO if the porter's exchange is connected through a D4L-R5
video distributor (recommended), if doing without this element, set to
video distributor (recommended), if doing without this element, set to
the OFF position.
the OFF position.
End of line resistor (Only in column encoder mode).
End of line resistor (Only in column encoder mode).
Set to Off in all converters except the last one (end of the coaxial
Set to Off in all converters except the last one (end of the coaxial
cable).
cable).
To be handled exclusively by Golmar personnel.
To be handled exclusively by Golmar personnel.
Set always to Off.
Set always to Off.
CONFIGURATION
CONFIGURATION