Installation And Wiring - LEGRAND Wattstopper TDA-603 Instrucciones De Instalación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

3. For 3-way/multi-way installations, the Touch Remote (TDR) must be used in conjunction with the TDA-603. The TDA-603 is not
compatible with standard 3-way/4-way switches.
4. For multi-way installations, do not exceed 200 ft. of traveler wire between all the devices.
5. It is normal for the dimmer to feel warm to the touch during operation.
6. Protect the dimmer from dust and dirt when painting and spackling.
Derating
No derating is required for up to 4 devices ganged together. When 5 or more devices are ganged together it is necessary to derate all
devices to 500W, regardless of the type of load that is being controlled.
For ease of installation, manufacturer recommends use of a deep wall box.
1. Prepare the switch box
After the power is turned OFF at the circuit breaker box, remove the
the old switch out from the wall box.
2. Identify the type of circuit
You may connect the TDA-603 to a single pole or multi-way circuit. If you are unable to clearly identify some or all of the wires
mentioned in this manual, you should consult with a qualified electrician. In a 3-way circuit (Fig.3) two traveler wires connect to
both switches. Another wire provides power from the circuit box to one of the switches. A wire connects from one switch to the
load. A ground wire may also be connected to a ground terminal on the old switches
Caution – For your safety: Connecting a proper ground wire to the dimmer provides protection against electrical shock in the event of
certain fault conditions. If a proper ground is not available, consult with a qualified electrician before continuing installation.
HOT (power from
circuit box)
NEUTRAL
LOAD
Ground
(power
to lamp)
Fig 2: Typical Single Pole
Switch Wiring
3. Prepare the Wires.
Tag the wires currently connected to the existing switch so that they can be identified later. Disconnect the wires. Make sure the
insulation is stripped off of the wires to expose their copper cores to the length indicated by the "Strip Gage" in Fig. 4. (approx. ½ inch)
4. Wire the dimmer.
a. Single Pole Circuit: Wiring one TDA-603 (Fig. 5)
• Connect the green or non-insulated (copper) GROUND wire from the
circuit to the green wire on the dimmer.
• Connect the power wire from the circuit (HOT) to the black wire on the
dimmer.
• Connect the neutral wire to the white wire on the dimmer.
• Connect the lamp power (LOAD) to the red wire on the dimmer.
• The yellow wire is not used in single pole applications.
b. 3-way/multi-way wiring (Fig. 6)
NOTE: In a 3-way/multi-way circuit the TDA-603 must be used in
conjunction with the TDR (Touch Remote). The
TDA-603 does not work if used in conjunction
with standard 3-way/4-way switches.
NOTE: The dimmer can go in either location.
• Connect the green or non-insulated copper
GROUND wire from the circuit to the green wire on
the dimmer.
• Connect the power wire from the circuit (HOT) to the
black wire on the dimmer.
• Connect the neutral wire to the white wire on the
dimmer.

INSTALLATION AND WIRING

MASTER SWITCH
NEUTRAL
LOAD/Common
(power to lamp)
GROUND
Fig. 3: Typical 3-Way Switch Wiring
NEUTRAL
120V/60Hz
(HOT)
Fig. 6: 3-way/Multi-way Wiring
WARNING: TURN THE POWER OFF AT THE
CIRCUIT BREAKER BEFORE WIRING.
existing wall plate and mounting screws. Pull
Lamp/load
AUXILIARY SWITCH
TRAVELER
TRAVELER
(power f rom ci rcuit box)
Load
NEUTRAL
120V/60Hz
(HOT)
Fig. 5: Single Pole Wiring
Load
Red
White
Black
2
Fig. 4 : #12 or #14 AWG
GROUND
HOT/Common
TDA-603
Red
White
Black
TDR
TDA-603
Green
GROUND
Yellow
Strip Gage
1/2"
12.7 mm
Green
GROUND
Yellow
Green
GROUND

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Wattstopper td-603

Tabla de contenido