5
PREPARING THE PLACE OF
INSTALLATION
5.1
ASSEMBLY DIAGRAM (FIG. 5.1)
A) For proper installation, the smoke ducting between the
replace and the ue must have all joints sealed.
B) External air intake (under re bed)
C) Uni standards require installaiton of a heeat recovery grille as
close as possible to the ceiling.
D) Counter-hood and reproof load-bearing structure
E) Cladding in ceramic bre or rock wool with external aluminium
foil
F)
Shield the wood parts with reproof material
G) Minimum distance 1 cm between cladding and replace
appliance.
H) The cladding must be made of reproof material.
Fig. 5.1.1 In the product technical detail shows the
minimum distances in centimeters to be observed
in the placement of the replace with respect to
materials and combustible objects.
Leave enough room for maintenance.
5.2

SAFETY PRECAUTIONS

The responsibility for any work done in the space where
the replace is to be installed is, and remains, the user's.
The user is also entrusted with carrying out the checks
regarding the proposed installation solutions.
Any wood beam of the cladding, or any finish in
combustible material, must be suitably insulated (or
located outside the area that is heated by the replace).
The user must comply with all the local, national and
European rules and regulations.
If the floor does not have a sufficient load-bearing
capacity, it is advisable to use a load-distributing plate
of an appropriate size.
The appliance must be installed on a floor with an
adequate carrying capacity.
If the floor does not have a sufficient load-bearing
capacity, it is advisable to use a load-distributing plate
of an appropriate size.
The replace assembly and disassembly operations must
be carried out by skilled technicians only.
It is always advisable for the user to call our assistance
service when they need quali ed technicians.
If other technicians are called in, please make sure they
are truly quali ed.
Before starting the assembly or dismantling phases of
the replace, the installer must comply with the safety
precautions as established by law, and in particular :
1.
he must not work in adverse conditions;
2.
he must be in perfect psychophysical condition to work
and ensure that the individual and personal accident
prevention devices are sound and in perfect working
order;
3.
he must wear accident prevention gloves;
32