Troubleshooting
Ice
PROBLEM
Refrigerator is
leaking water
Ice forms in inlet
tube to ice maker
POSSIBLE CAUSES
Supply tubing was used to complete
water connection.
Improper water valve was installed.
Water pressure is low.
Freezer temperature is too high.
WHAT TO DO
The manufacturer recommends using copper tubing
for installation. Plastic is less durable and can cause
leakage. The manufacturer is not responsible for
property damage due to improper installation or
water connection.
Check water connection procedure. Self-piercing and
0.5 cm saddle valves cause low water pressure and
may clog the line over time. The manufacturer is not
responsible for property damage due to improper
installation or water connection.
Water pressure must be between 137 to 689 kpa to
function properly.
Adjust Freezer control (see page 8). Freezer is
recommended to be approximately -18° C.
20