INSTALLATION
USING THE DISPLAY
5.
Using the display
5.1
User input
The Tempra Trend and Tempra Plus feature an interactive display
that allow for user customization to increase the level of comfort
for the user.
The menu structure is designed in an intuitive, linear way to make
it as navigable as possible.
5.1.1 Tempra Trend user input
User input
T
button (pressing or holding this button
max
performs different functions)
Control knob (turn knob to change settings)
5.1.2 Tempra Plus user input
User input
Information button (pressing or holding this
button performs different functions)
Preset 1 button (pressing or holding this but-
ton performs different functions)
Preset 2 button (pressing or holding this but-
ton performs different functions)
Control knob (turn knob to change settings)
5.2
Tempra Trend display
The Tempra Trend display features a temperature and power capa-
city display. The display is backlit and will illuminate whenever
user input is detected. The backlight will time out and deactivate
if no user input has been detected for 15 seconds.
For the name of each display element on the Tempra Trend, consult
section 4.1.1, "Tempra Trend", pg. 4.
WWW.STIEBEL-ELTRON-USA.COM
5.2.1 Base display
The base display shows the current temperature setpoint in your
preferred temperature unit. The bar below the temperature shows
the current operating capacity. As the hot water demand fluc-
tuates, the power capacity status will change to show between 0
and 10 segments. The display below shows that the water heater
is operating at 40% of capacity.
All other menu displays will revert back to the base display either
after a 15 second period of time without user input, or after a 5
second hold of the T
button.
max
Changing the setpoint temperature
The setpoint temperature can be set between 68°F (20°C) and
140°F (60°C).
The setpoint can be increased by turning the control knob
clockwise, and decreased by turning it counter-clockwise. The
water heater can be deactived while still powered by turning the
control knob counter-clockwise, past the 68°F (20°C) setting.
5.2.2 Parameters menu
While at the base display, holding the T
will advance the display to the first parameter menu.
T
parameter setting
max
The first parameter menu sets the value for T
T
acts as a high temperature limiter. If the T
max
setpoint of the water heater cannot be set above the T
This feature is useful in scenarios where scalding from hot water
is a real possibility.
At the T
setting menu, the display will flash, indicating that
max
the value can be changed by rotating the control knob. The T
value can be increased by turning the control knob clockwise, and
decreased by turning it counter-clockwise. The T
deactived by turning the control knob counter-clockwise, past the
68°F (20°C) setting. The display will read "Off" if T
If the T
symbol is visible at the base display, then the T
max
tion is active and is limiting the maximum allowable temperature
to the preset level.
TEMPRA TREND & TEMPRA PLUS |
button for 5 seconds
max
. The value of
max
value is set, the
max
value.
max
max
value can be
max
is inactive.
max
func-
max
5