Drain Assembly; Washbar Installation - Bradley OmniDeck 5000 Serie Manual De Instalación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

LD-5010
1

Drain Assembly

For ease of drain installation, lay the bowl on its back.
Assemble the remaining
components as shown and
thread the four screws through
the drain adapter and into
A
the basin inserts. Ensure the
screws compress the drain
adapter evenly onto the basin.
NOTICE! Do NOT
overtighten drain
adapter screws.
2

WashBar Installation

WashBar comes pre-assembled,
with the exception of the aerator.
When attaching flexible
PVC dryer tube, be
sure tube is touching
the WashBar nut when
complete.
A
Position bowl on the
floor, upright, as shown.
B
Assemble WashBar through basin
WashBar holes. Run cables and
tubes on left side only.
Soap Tube (Clear), 1/4" Water
Tube, LED Cable (Gray), Soap
Sensor Cable (Shorter Cable) and
Air/Water Cable (Longer Cable)
14
WashBar
11/21/2019
O-Ring
Drain
Adapter
Packing
Washer
Single station shown; 2 station similar.
Connect grounding wire spade
E
terminal end to grounding washer
tab. Do not attach grounding wire
plug adapter to wall outlet until later
in the installation procedure.
Grounding Washer,
Attach flexible PVC
.25 QC
D
dryer tube to shank
using hose clamp.
Tighten to 30-35 ft. lbs
using 5/16" socket.
Nut, WashBar,
1-3/8-18
Secure from underside
C
with (2) nuts and (1)
grounding washer (right
side only).
F
Attach the 1/4" supply
tube to the 1/4" union
elbow.
Bradley • 215-1869 Rev. E: ECO 19-11-006
Installation
#10-24
Screw

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Omnideck ld-5010

Tabla de contenido