Installation
3

Aerator Installation

Carefully thread the aerator into
A
the WashBar casting using the red
service key provided. Ensure no
leaks after installation.
4

Attach Soap Motor and Soap Container Bracket

Attach soap motor control box and
A
soap container bracket to wall using
#10 fasteners at locations shown in
Structural Rough-In drawing.
B
Install the soap pump onto gallon
container opening (supplied by
others).
The liquid soap pump has a rubber
sleeve that fits over the soap
container opening. The foam soap
pump has an interior white cylinder
that fits into the soap container.
This fit up may be tight. Move the
soap pump laterally while applying
pressure to seat into soap container
opening.
To check soap fitup, slide gallon jug
with soap pump into soap motor
control box. Ensure soap pump flange
C
is positioned below motor control box
lever and soap control box flange
is positioned in soap pump groove.
Gallon jug should rest on soap
container bracket without soap pump
pulling off of container.
Once fitup is correct, remove soap
D
container with pump attached and set
aside. Soap container will be installed
in a later step.
Bradley • 215-1869 Rev. E: ECO 19-11-006
Soap Motor
Control Box
Container
Bracket
Soap Pump
Flange
Soap Pump
Groove
Aerator
(0.35 gpm or
0.5 gpm)
Soap
Red Service Key
13"
15-1/2"
(330)
(394)
6-5/8"
(168)
Soap Supply
Tube
Motor Control
Box Lever
Soap Control
Box Flange
11/21/2019
LD-5010
12"
(305)
Liquid soap pump
shown. Foam soap
pump similar.