Installation
Installation
Supplies Required:
• (3)
⁄
" floor anchors and bolts
3
8
• Teflon tape and pipe sealant
• Piping to 1¼" NPT water supply inlet and 1¼" NPT
drain outlet on unit
• Adequate supply pipe supports
• Minimum 4" (102mm) drain to accommodate 30
gallons (115 liters) per minute discharge for shower
waste
• OPTIONAL: sign-mounting hardware
NOTE: Local codes may require the installation
of a backflow prevention valve to complete proper
installation. Compliance with local codes is the
responsibility of the installer. Valve must be tested
annually to verify that it is functioning properly. Backflow
prevention valves are not included with the fixture and
may be supplied by the contractor or purchased from
Bradley Corporation.
Step 1: Secure base to floor
1. Install three suitable anchors (supplied by installer)
for
⁄
" bolts in the floor.
3
8
2. Bolt the base to the floor anchors using
(supplied by installer).
Step 2: Assemble components
1. Assemble the remaining unit components as
shown on page 4. For ease of installation,
disassemble the union (#18) prior to assembly.
• Apply pipe sealant (by installer) to all male-
threaded pipe joints.
• Use the rubber grip pad provided or a strap
wrench around pipes when tightening to prevent
marring the Bradtect® protective, safety yellow
coating. Place the grip pad on the pipe, then put
the wrench over the grip pad and turn the pipe
with the wrench.
• Bottom edge of the showerhead should be 86"
(2180mm) from floor.
Step 3: Connect water supply
IMPORTANT: Do not rely on Bradley's
Combination Unit to support supply piping.
1. Connect water supply piping to 1¼" NPT inlet
on unit (piping by installer). Provide adequate
supports (by installer) for supply pipe using pipe
hangers or other means.
2. Connect drain piping to 1¼" NPT drain outlet on
unit (piping by installer).
3. Hang the safety sign from the unit with the curtain
hooks provided (or mount it to the wall using sign-
mounting hardware by installer).
Bradley • 215-163 Rev. G; ECN 12-05-016D
4½"
(114mm)
(78.7mm)
86"
(2184mm)
to Bottom
of Base
⁄
" bolts
3
8
(254mm)
NOTE: All dimensions assume standard thread
engagement. Variations in manufacturing allow for
+/-
⁄
" (3mm) per threaded joint. To find the tolerance
1
8
of a dimension, add the number of thread joints in
between a dimension and multiply it by
25
⁄
"
3
8
(645mm)
Ø 3.1"
9"
(229mm)
68½"
(1740mm)
to Bottom
of Base
42"
(1067mm)
to Bottom
of Base
6"
(152mm)
9½"
(241mm)
Ø 10"
10½"
(267mm)
Top View From Bowl
5/30/12
S19-310
94
⁄
"
1
8
(2391mm)
to Bottom
of Base
66"
(1676mm)
to Bottom
of Base
36
⁄
"
3
8
(924mm)
to Bottom
of Base
Ø 9" (229mm) Flange
with (3) Ø
⁄
" (10mm)
3
8
Holes on Ø 8" (203mm)
Bolt Circle
⁄
" (3mm).
1
8
3