IMPORTANT INSTRUCTIONS

WARNING: Risk of scalding or other severe injury.
• Before completing installation, the installer must set the maximum water
temperature setting of this valve to minimize the risks associated with scalding
hazards according to ASTM F 444.
• Do not install a shut-off device on either outlet of this valve. The installation of
any such device may create a cross-flow condition at the valve and affect the
water temperature.
• Factors that change the temperature of the water supplied to the valve, such as
seasonal water temperature changes, and water heater replacement or servicing,
will change the maximum water temperature supplied by the valve and may
create a scalding hazard. The pressure-balancing valve will not compensate for
changes in the water supply temperature; adjust the maximum water temperature
setting of this pressure-balancing valve when such changes occur.
• Pressure-balancing valves may not provide protection against scalding if there is a
failure of other temperature-limiting devices elsewhere in the plumbing system.
NOTICE: Only apply silicone based lubricants to these valves. Do not use petroleum
based lubricants. Petroleum based lubricants will harm the O-rings, seals, and plastic
components.
The installer is responsible for installing the valve and adjusting the maximum water
temperature of this pressure-balancing valve according to instructions.
This valve meets or exceeds ANSI A112.18.1 and ASSE 1016.
If you do not understand any of the installation or temperature adjustment instructions
in this document, in the United States please contact our Customer Service Department
at 1-800-4KOHLER. Outside the U.S., please contact your distributor.
The PEX connections on the 304-PX and 304-PS are designed for use with any ASTM F
1807 compliant copper crimp rings and ASTM F 887 compliant PEX tubing. These fittings
are not compatible with ASTM F 1960 cold expansion fittings with PEX reinforcing ring
assemblies.
The PEX fittings on this valve have been third party certified by CSA using the following: Sioux Chief 1/2" copper
crimp ring and CSA certified VANGARD VANEX
1/2" crimp tool in accordance with the Sioux Chief instructions.
The PEX connections on the 304-UX and 304-US are designed for use with any ASTM F
1960 compliant cold expansion retaining rings and ASTM F 887 compliant PEX tubing.
These fittings are not compatible with ASTM F 1807 copper crimp reinforcing ring and
PEX tubing assemblies.
The PEX fittings on this valve have been third party certified by CSA using the following: WIRSBO AQUAPEX 1/2"
potable tubing, Upnor ProPEX 1/2" cold expansion retaining rings and the Uponor ProPEX Hand Expander tool in
accordance with the Uponor Instructions.
IMPORTANT NOTICE TO INSTALLERS! Please fill in the blanks in the information
box in the Homeowners Guide and on the valve label. Retain the Homeowners Guide for
future reference.
NOTICE TO HOMEOWNERS! This device has been preset by _______________________
of _______________________________ to ensure a safe maximum temperature. Any
change in the setting may raise the discharge temperature above the limit considered
safe, and lead to scalds.
Date: ______________
1110626-2-G
1/2" PEX potable tubing. Crimps were made using a Sioux Chief
®