Features
• Easy installation with strip terminal
• Output adjustable from 12V to 15V
• Tight regulation: 0.05% Line; 0.05% Load
• Full Output Ratings to +50
C
o
• Built in OVP on 5 Volt Outputs
• OVP Option for 12V and 15V
• Foldback Current Limiting Overload Protection with
Automatic Recovery
General Specifications
Voltage/Current Ratings
Model Number
Output 1
SLT12-20404-12T
5V@2A
*Outputs are tied common
Operating Temperature Range
0 to +50
o
C (Derate to 40% at +70
Temperature Coefficient (Typical)
+/- 0.01% /
Stability
Within +/- 0.05% (For 24 hours after warm-up)
Vibration
Per MIL-STD-810C, Method 514
Shock
Per MIL-STD-810C, Method 516
Linear power supplies have inherently low conducted and radiated noise levels.
EMI/RFI
For most system applications, these power supplies will meet the requirements
of FCC Class "B" and VDE 0871 for Class "B" equipment without additional
noise filtering.
Forced air. 20 CFM required for full rating Derate 30% for convection cooling.
Cooling
Input Specifications
Multi Input (all units)
100/120/220/230/240 VAC selectable +/- 10% except 230 VAC is +15%, -6%
Frequency Range
47-63 Hz (Typical is 60 Hz. Derate output 10% at 50 Hz)
Transient Response Time
50 µsec at 50% load change
Fuse Requirements
Units are not fused internally. For safe operation, user must provide input line
fuse as per values given in table.
Output Specifications
Line Regulation
0.05% for +/- 10% change
Load Regulation
0.05% for 50% change
Ripple
3.0 mV maximum peak-to-peak
DC Output Adjustment Range
+/- 5% minimum
Overvoltage Protection
All 5 volt outputs include built-in OVP as standard (setting is 6.2V +/-0.4V).
OVP is optionally available on other outputs.
Overload Protection
125 to 150% foldback current limit
Contact Technical Services at 1-800-377-4384 or tech@sola-hevi-duty.com with any questions.
Visit our website at www.solaheviduty.com
Linear Open Frame DC Power Supplies
Silver Line Instruction Manual
Model: SLT12-20404-12T
• Multi-Tap AC Inputs
• 100% Four-Hour Burn-in
• Please see enclosed "Terms & Conditions and
Sales & Policies & Procedures"
• UL Recognized
• CSA Certified
Output 2
Output 3
+12V@.4A or +15V@.4A
-12V@.4A or -15V@.4A
o
C)
o
C
Output Adjustment
Step 1:
Check the input AC connections
Step 2:
Connect the AC input according to table below.
Step 3:
Use VR6 to adjust +V. Adj. to +15V or +12V.
Step 4:
Use VR4 to adjust -V. Adj. to -15V or -12V.
Input AC Connections
For use
at:
Connect
100 VAC
1-3, 2-4
120 VAC*
1-3, 2-4
220 VAC
2-3
230 VAC
2-3
240 VAC
2-3
*Note: Unit is shipped for 120V input from factory.
Mechanical Dimensions: inches (mm)
Note: I. LIM is factory set and should not be adjusted by users.
Application Note: User needs to provide earth ground to power supply with either solder to Tab or using washer and
nut assembly.
The SLT power supply is shipped from the factory with metal shorting straps connected between
the + OUT and + S terminals and the (-) OUT and (-) S terminals. This strapping configuration
allows the output of the SLS to be taken from either pair of terminals. This is the
standard configuration.
The remote sense feature is enabled by removing the shorting straps and connecting the
individual OUT and S terminals to the appropriate points of the load. If an OVP circuit is used it
should be connected to the + OUT and (-) OUT terminals. The OVP should never be connected
to the + S, - S terminals without the use of the shorting straps. In all cases it is critical that the
terminal screws be firmly tightened.
Contact Technical Services at 1-800-377-4384 or tech@sola-hevi-duty.com with any questions.
Visit our website at www.solaheviduty.com
Apply AC to:
Primary Fuse
1 & 5
0.63A/125V
1 & 4
0.63A/125V
1 & 5
0.315A/250V
1 & 4
0.315A/250V
1 & 4
0.315A/250V
Case H2