CONNECTIONS
24
+24
23
-24
22 OPEN
21 PED/CL
20
SEQ
19
STOP
18
PH1
17
PH2
M1
16
SAF
15
COM
14
+AUX
13
+TST
12 +LOCK
11 -LOCK
10 M2CL
9 M2OP
8 M2COM
7 M1CL
M2
6 M1OP
5 M1COM
4
L
3
N
2 PE
M3
1 PE
25 GND
M4
26 ANT
CN2
Additional module connector for second channel output
K3
Three-pin connector for accessories insertion; UNICO receiving radio board connection
(alternative to the integrated receiving unit) - Access control decoder.
(1) Opening - Stop - Closing - Stop - etc.
(2) Opening - Closing - Opening - etc.
(3) The courtesy function enables the closing 5 seconds after the photocells have received the pulse, regardless of the set
stop time.
(4) The condominium function disables the SEQ and PED controls during opening
(5) Release stroke:
When opening is enabled, this is preceded by a short movement in the other direction in order to remove
the load on the wings and make it easier to release the electric lock.
Hooking stroke:
When closing is enabled, this is followed by a short full power activation in order to make it easier to block the
electric lock.
Description
Accessory power supply 24 V DC
It controls the opening if the gate is stopped.
If the gate is closing, it inverts the movement.
It controls the pedestrian opening if the gate is closed.
It controls the pedestrian closing if the gate is opened or stopped.
It controls the opening if the gate is closed.
It controls the closing if the gate is opened or stopped.
It controls the stopping of every movement and, if enabled, it prevents any movement.
Photocell 1 input: during closing, it inverts the movement and, if enabled, it prevents
closing.
Photocell 2 input: it stops any movement. If enabled it prevents any movement. When
disabled: opening.
Safety Input: it stops every movement and causes a short suspension. If enabled it
prevents any movement.
Common inputs
Remote warning light of automation status:
• flashing fast during closing;
• flashing slow during opening;
• fixed light: swing gates NOT closed;
• light off: swing gates closed
If dip 9 ON: Safety devices test Out (see 9.)
If dip 9 OFF: LED flashing light Out
Lock 12 V AC Out
Lock 12 V AC Out
Wing 2 Motor Closing
Wing 2 Motor Opening
Wing 2 Motor Common
Wing 1 Motor Closing Winding
Wing 1 Motor Opening Winding
Wing 1 Motor Common
Phase 230 V AC
Neutral 230 V AC
Functional earth 230 V AC
Functional earth 230 V AC
Radio Antenna Ground Connection
Radio Antenna Pole
BA230