PH1
At the beginning of the closing manoeuvre
PH2
At the beginning of the closing and opening
manoeuvres
SAF
At the beginning of the closing and opening
manoeuvres
During stroke memorization the supervised safety devices are automatically recognised.
If no supervised device is recognised and dip 9 is set to ON, the following safety device tests will fail and the gate will not
move!

3) SAVING THE REMOTE CONTROLS

The equipment BA230 is provided with an integrated decoder able to store up to 250 remote controls.
1.1 SEQ Function
Press the P2 button until the PROG LED starts flashing. Release P2.
Enable the remote control key that you want to assign to the SEQ control within 10 seconds. Saving is completed when the
PROG LED will flash for a longer time.
Repeat the operation for each remote control to save.
1.2 PED Function (or CH2)
Press P2 button until PROG LED starts flashing; do not release P2 and wait for the flashing to become faster. Release P2
button
Enable the remote control key to be saved that you want to assign to the PED control within 10 seconds. Saving is completed
when the PROG LED will flash for a longer time.
Repeat the operation for each remote control to save.
1.3 Deleting a single remote control
Press P2 button until PROG LED starts flashing; do not release P2 and wait for the flashing to become faster; do not release
P2 and wait for the flashing to become very fast. Release P2 button.
Enable the key of the remote control that you want to delete within 10 seconds. Delete operation is completed when the
PROG LED will flash for a longer time.
Repeat the operation for each remote control to delete.
1.4 Deleting all remote controls
Switch the equipment on by pressing the P2 button until the PROG LED starts flashing; do not release the button and wait for
the flashing to stop. ALL remote controls are deleted when the PROG LED will flash for a longer time.
1.5 Module Channel MCH2 function
To enable dell'MCH2 command with the second radio control channel:
press the P2 button until the PROG LED starts blinking; not release P2 and
wait until the flash gets quicker; not release P2 and wait for the flashing
become even faster; Release the P2 button.
Continue with point 1.2 to learn the second channel of a TM4 associated all'MCH2
1.6 DATA OUTPUT MCH2 ( MAX 1 A a 24VDC )
CN2 connector can be connected to the coupon MCH2.
This board provides two NC and NO contacts that are activated for 1 sec at the reception of a
pulse from a remote control button associated with MCH2
If no remote control has been associated with MCH2 contacts are activated for about 1 sec in
Following a SEQ command, PED, or OPEN.
4) STROKE PROGRAMMING
NOTE After the board has been powered, the stroke time of the first closing manoeuvre is increased by about 12
seconds so that the movement can be completed.
During saving, beside saving the slowing down spaces and the pedestrian opening stroke, the equipment will detect any
supervised safety input PH1, PH2 or SAF.