2.5 List of cables needed

Typical installation cables required for connection of various devices
are shown in cables list table.
CABLES LIST TABLE
Connection
Power supply line
Flashing light
Transmitter photocells
Receiver photocells
Key selector
Fixed edges
Mobile edges
Antenna with RG58 shielded cable

3 - PRELIMINARY CHECKS

Before installing this product, verify and check the following steps:
- Check that the gate or door are suitable for automation
- The weight and size of the gate or door must be within the operat-
ing limits specified for the automation where the product is installed
- Check the presence and strength of the security mechanical stops
of the gate or door
- Check that the mounting area of the product is not subject to flood-
ing
- Conditions of high acidity or salinity or proximity to heat sources
could cause malfunction of the product
- Extreme weather conditions (for example the presence of snow,
ice, high temperature range, high temperatures) may increase the
friction and therefore the force required for the handling and initial
peak may be higher than under normal conditions.

4 - PRODUCT INSTALLATION

4.1 Assembly of chain in 3 parts

1. Line the three pieces of the guide
2. Place the connector at the center of the guide and between the
limits position, then repeat for the second connector.
Limit position
3. Tighten the nut with a wrench Ø 13
18
da 1 a 10m
3 x 1,5 mm
2 x 0,5mm
2
2 x 0,5mm
2
4 x 0,5mm
2
3 x 0,5 mm
2 x 0,5 mm
2 x 0,5 mm
RG58 Shielded cable max 10m
Limit position
Connector
The cables used must be suitable for the installation; for example,
we recommend a H03VV-F type cable for indoor installation and
H07RN-F for outdoor.
da 10 a 20m
3 x 1,5 mm
2
2
2 x 0,5mm
2
2 x 0,5mm
2
4 x 0,5mm
2
3 x 0,5 mm
2
2
2 x 0,5 mm
2
2
2 x 0,5 mm
2
2
- Check that the manual operation of gate or door is smooth and
friction-free and there is no risk of derailment
- Check that the gate or door are balanced and stationary if left in
any position
- Check that the power line to supply the product is equipped with
proper grounding safety and protected by a magnetothermal and
differential security device
- Provide the power system with a disconnecting device with a gap
beween contacts enabling full disconnection under the conditions
dictated by the overvoltage category III.
- Ensure that all materials used for the installation comply with cur-
rent regulations
4. Adjust as indicated in the chain draught diagram
For a correct adjustment ensure that during movement of the door
the chain does not slide out of the tracks (too loose) or on the con-
trary tends to bend the tracks (too tight)
about
da 20 a 30m
3 x 2,5 mm
2
2 x 0,5mm
2
2 x 0,5mm
2
4 x 0,5mm
2
3 x 0,5 mm
2
2 x 0,5 mm
2
2 x 0,5 mm
2

Hide quick links:

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Viper sez7uViper sez7Viper sez12uViper sez12Viper sez124Viper

Tabla de contenido