PRELIMINARY CHECKINGS

Before installing AZIMUT, please check the following basic points:
• The door must be suitable to be automated (check the door
operation manual and directions). The door structure itself
must be stout and appropriate to be automated.
• Fix the engine steadily and using suitable material.
• If necessary, make the structural calculation and enclose to
the technical specification paper.
• Check the door to be provided with anti-fall system
(independent of the suspension system)
• The door must be functional and safe.
• The door must open and close easily without any friction.
• The door must be properly balanced both before and after its
automation: stopping the door in any position, it must not
move (carry out a balance weight adjustment, if necessary).
• It is advisable to install the geared motor in the centre of the
door.
• In case of counterbalanced door, check that the minimum
distance between the track and the door must not be under
20 mm.

INSTALLATION LAYOUT

Actuator AZIMUT
Photocells
Key switch
Inside push-buttot panel
Schuco socket
Junction box
27
cable with plug 2 x 0.75 mm
2
cable 4 x 0,5 mm
2
(RX)
cable 2 x 0,5 mm
2
(TX)
cable 3 x 0.5 mm
2
cable 3 x 0,5 mm
2
-
-