POSSIBLE TROUBLESHOOTING
1)
Air ow may be insuf cient because the door is open, the door does not close properly (e.g. bad seal), there is an
air inta e or smo e extraction problem, or the combustion chamber is clogged.
Chec :
door closure;
combustion air inta e duct (clean, paying attention to the ow sensor components);
clean the ow sensor with dry air (li e that used for C eyboards);
stove location: it must not be installed against a wall;
combustion chamber position and cleanliness (clean regularly according to the type of pellet);
smo e duct (clean);
installation (if it does not comply with regulations or the smo e outlet has more than - bends);
If you suspect the sensor is malfunctioning, carry out cold tests. If the conditions are changed (for example by
opening the door) and the value does not change, there is a sensor problem.
he no depression alarm may also occur during ignition, since the ow sensor starts monitoring 9 seconds after
the ignition cycle begins.
Chec smo e extractor function (devolution sensor connection) and board (DEALER).
Chec smo e channel for dirt
erify the electrical system and earthing system.
Chec eletronic circuit board (DEALER).
interprets as the absence of ames)
urns off due to drop in smo e temperature
lac of pellets
too many pellets have suffocated the ame, chec pellet quality (DEALER)
the maximum thermostat has intervened (rare, this only intervenes in the event of excessive smo e
temperature) (DEALER)
temperature is not reached).
Distinguish either of the following cases:
Chec : - combustion chamber position and cleanliness;
arrival of combustion air in the combustion chamber;
if the heating element is wor ing (DEALER);
room temperature (if lower than
ry to light with a relighter (see page
Chec : (only by the Dealer)
if the thermocouple is wor ing (DEALER);
start-up temperature setting in the parameters (DEALER).
Repeat start up after having emptying the brazier.
Chec electricity connection and drops in voltage.
Chec connection of thermo coupling to board: chec function in cold test (DEALER).
(intervenes if the ow sensor detects insuf cient combustion ).
(this trips if the smo e extraction speed sensor detects a fault)
(this trips if the thermocouple detects a smo e temperature lower than the value set, which it
(intervenes if a ame fails to appear within a maximum of
C use a relighter) and damp.
(not a defect of the stove).
(intervenes if the thermo coupling has failed or is disconnected).
).
- 37
-