USER'S MANUAL PROLITE-65
4.2.3.2
POWER METER Function.
This function allows you to measure optical power at xPON or RFoG network
wavelenghts. The network type is configurable by the user (see section
CONFIGURATION function). In this way, the instrument connects in "pass-trhough"
mode, that is, without interrupting the service, allowing to measure simultaneously
Upstream and Downstream power signal.
To access this function:
1.-
Press CONFIG
2.-
Press
3.-
Press SEL
below).
Next are described each one of the fields on screen:
[1]
Upstream (1310 nm) signal status with respect to threshold values. Three
states are possible: LOW, PASS, HIGH.
[2]
Upstream wavelenght signal (OLT).
[3]
Downstream wavelenght signal (ONT).
[4]
Downstream (1490 / 1550 nm) status signal with respect to the threshold
values. Three states are possible: LOW, PASS, HIGH.
07-2010
[2].
or
[5] until pointing at xPON / RFoG POWER METER.
[4] or CONFIG
Figure 9.- POWER METER screen.
[2] to get into this function (see figure