[5]
Absolute optical power of the signal at the corresponding wavelenght.
Absolute measurement mode is the absolute power of signal in dBm (dB
referred to 1mW).
[6]
It is an arrow which indicates if the value exceeds (arrow pointing up) or does
not arrive (arrow pointing down) to the minimum levels in order to be
graphically represented.
[7]
Graphical representation of the Downstream power.
[8]
Threshold group of values selected for Downstream. Threshold values are
grouped and saved on the memory of the instrument, then later they can be
selected in order to the quality criterium to meet.
[9]
Upper threshold value for Downstream.
[10] Lower threshold value for Downstream.
[11] Graphical representation of the Upstream power.
[12] Selected threshold group of values for Upstream. Threshold values are
grouped and saved on the memory of the instrument, then later they can be
selected in order to the quality criterium to meet.
[13] Upper threshold value for Upstream.
[14] Lower threshold value for Upstream.
[15] Absolute optical power of the signal for Upstream. Absolute measurement
mode is the absolute power of signal in dBm (dB referred to 1mW).
[16] The OLT led indicates the status of the OLT signal with respect to the
threshold values. Three indicator lights colours are possible and each colour
represents status signal with respect to threshold values: GREEN (PASS),
AMBER (HIGH) and RED (LOW).
[17] The ONT led indicates the status of the ONT signal with respect to the
threshold values. Three indicator lights colours are possible and each colour
represents status signal with respect to threshold values: GREEN (PASS),
AMBER (HIGH) and RED (LOW).
To navigate through the editable fields on the screen press SEL
selected field changes to shaded.
To edit a wavelenght or a threshold group of values, select it and press
[5].
Page 20
USER'S MANUAL. PROLITE-65
[4]. The
or