Automatic Disarming | Uf; Configuring Display Lighting | Uf; Hold Function | Uf - Baxtran BR16 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

5. The display will show the message "000.00h" (Superior limit=Hi)
6. Use the keys
and
Note: If you need to change or modify the last digit you can place the cursor on it to do it.
7. Press the key
to confirm.
8. The display will show the value.
DISPLAY
VALUE
A
0
1
B
0
C
0
1
2
9. Press the keys
and
10. Press the key
to confirm.
The indications on screen
Lo, Ok , Hi
8.3 AUTO SWITCH OFF| UF-3
MODES:
AoFF 00 – Auto switch off deactivated
AoFF 01 – Auto switch off activated in a minute. The scale is going to switch off automatically after 1 minute of not being used.
• You can configure the value wished from 1 to 99 minutes.
1. Press the key
to have an access to the parameter.
2. Press the keys
and
3. Press the key
to confirm.
8.4 DISPLAY BACKLIGHTING | UF-4
MODES:
A: Automatic.
ON: Illumination Activated.
OFF: Illumination Deactivated.
1. Press the key
to have an access to the parameter.
2. Press the key
to select the desired mode.
3. Press the key
to confirm.

8.5 HOLD FUNCTION | UF-5

(Once the object is retired from the plate, the display maintains the weight fixed during some seconds. This function is very useful for the weighing of
animals)
to move the cursor and the key
(configuration of the alarm)
ESTABILITY
There is no need to stabilize the alarm to make it ring
The alarm must be stabilized to ring
Always 0
Alarm switched off
The alarm ring if it is place on the band OK
( between the limits Lo and Hi)
The alarm rings if it is situated below the
inferior limit Lo or above the superior limit
Hi
to move the cursor and the key
will appear on screen depending on the weight.
to move the cursor and the key
to choose the desired number.
A
B
C
0
0
0
LO
OK
LO
OK
to choose the desired number..
to choose the desired number.
USER'S MANUAL BR16
HI
HI
EN
55