6.2.3 Operation with room probe
In certain circumstances it may
be useful to ensure that the stove
modulates its operation based on the
temperature read by the room probe
on the stove itself (Fig. 6.2.3).
It is important to set the stove
in configuration 2 following
the instructions in the "Initial
configuration" paragraph.
6.2.4 Connection to a storage tank with coil
It is possible to ensure that the stove
maintains a storage tank with coil at
the correct temperature.
In this case simply disconnect the
room temperature probe on board the
stove and extend it to the probe well
on the storage tank (Fig. 6.2.4).
It is important to set the stove
i n c o n f i g u ra t i o n 3 f o l l o w i n g
the instructions in the "Initial
configuration" paragraph.
6.2.5 Connection to a storage tank without coil
It is possible to ensure that the
stove maintains an accumulation
tank without a coil at the correct
temperature.
In this case simply disconnect the
temperature probe on the stove and
extend it up to the probe well, present
on the storage tank
It is important to set the stove
i n c o n f i g u ra t i o n 4 f o l l o w i n g
the instructions in the "Initial
configuration" paragraph.
(Fig. 6.2.5).
004778021 - 10/01/2020 - PN - Italy
Ambient temperature
1
6
Puffer probe
1
6
Puffer probe
1
6
probe
Fig. 6.2.3
Fig. 6.2.4
Fig. 6.2.5
51