It is possible to set the "Eco-mode" function so that the stove switches off or on again
according to the set room temperature.
Configuration 3
Set this configuration when it is intended to connect the stove to a storage tank with
coil.
The stove will be controlled (on and off) by the temperature read by the storage probe.
The antifreeze function can also be set in this configuration.
Configuration 4
Set this configuration when it is intended to connect the stove to a storage tank
without coil.
The stove will switch on according to the temperature read by the storage probe,
and will switch off based on the return temperature of the stove.
The antifreeze function can also be set in this configuration.