GB
The Hozelock Cyprio Cascade 2000, 3000 &
4000 low voltage pumps are designed for
submersible use only. The pumps do not use
oil or grease for lubrication and can be used
safely in ponds containing fish or plants. The
motor consists of a sealed stator and water-
cooled permanent magnet rotor. All electrical
components are isolated from the water.
WARNING: SAFETY AND
ELECTRICAL CONNECTIONS.
1. WARNING - Always unplug or disconnect
all appliances in the pond from the
electricity supply before putting your
hands in the water whilst equipment is
being installed, repaired, maintained or
handled.
2. Position the transformer in a garage or
shed close to the mains voltage supply.
The transformer is not waterproof and
must be kept dry and under cover –
allowing for sufficient air circulation.
Do not position the transformer in direct
sunlight, eg.. greenhouse, window sills,
etc.. as high temperatures may cause
overheating.
3. Do not use the supply cable to lift the
pump, as this may cause damage. We
recommend fitting a lifting cord to the
handle eye on the top of the strainer cage
when the pump is installed in deep water.
4. Do not operate or leave the pump in
freezing conditions.
5. Do not allow the pump to run dry.
6. Check that the voltage marked on the
pump corresponds to the low voltage
supply.
7. Do not operate this pump without the
strainer cage attached. Using the pump
without a strainer may invalidate your
warranty.
8. The pump must only be connected to a
safety isolating transformer with a 24V
output, such as the one supplied with this
product.
9. Consult a qualified electrician or local
authority if in any doubt about wiring to
the mains supply.
ACCESSORY ASSEMBLY
Tee Piece.
1. Locate the fountain flow adjuster (Fig1- A)
to the tee piece body with the peg
positioned downwards to engage in the
tee. Push in fully and snap them together.
2. Locate the valve stem (B) to the waterfall
flow adjuster (C) and snap them together.
Screw the valve assembly into the longer
boss (D) on the tee piece. See Fig 1.
Telescopic Stem
1. Slide the Inner Tube (E) through the
Telescopic Stem Nut (F) and "O" ring (G).
Push the Inner Tube into the Outer Tube
(H) and gently screw down the nut. The
finishing position of the tee piece is not
important. The maximum to minimum
range of the Telescopic stem is 150mm
(6") (See Fig 2).
Bell Fountain.
1. Locate the Bell Support (J) to the Bell
Main Body (I) and push fully home.
2. Position the Bell (K) to the Body Assembly
and press into the central location.
See Fig 3.
TRANSFORMER INSTALLATION
Connect the pump to the transformer as
follows. (See figure 10)
U
..
..
Mains voltage cable
V
..
..
Low voltage cable to
pump
W ..
..
Flying Lead
2
Note: If the transformer supplied with this
product is marked with a Ref No. 24.758, it is
fitted with a re-settable overload switch. If
the transformer is short circuited the fault
must be found before the rubber covered
switch is pressed to reset the unit.
1.
Screw the transformer into position on
the wall ensuring easy access to the low
voltage terminal block.
2.
Plug the pump lead into the socket
provided on the flying lead for the
transformer. If an extension lead is
required Hozelock Cyprio provide
extension leads ref Hozelock Cyprio
Consumer Services.
3
The cable supplied with this pump
cannot be replaced, if the cable is
damaged.
WARNING: THE PLUG SUPPLIED WITH
THIS PRODUCT IS NOT WATERPROOF
AND THE CONNECTION TO THE MAINS
SUPPLY SHOULD ONLY BE MADE IN A
WEATHERPROOF ENCLOSURE.
Ensure 230v cable and 24v cables do
not cross.
Brown - Live
Blue - Neutral
The BROWN lead should connected to
the LIVE terminal, which may be marked
with an 'L' or coloured brown or red.
The BLUE lead should be connected to
the NEUTRAL terminal, which may be
marked with an 'N' or coloured blue or
black.
Note:
This transformer is protected by a self-
resetting thermal cut-out. If this device
operates the pump will stop working.
Switch off and allow the transformer to cool
for two hours before re-starting.
Continual tripping can be caused by installing
the transformer in hot locations (eg direct
sunlight).
PUMP INSTALLATION
Position
Construct a solid and level platform on which
to place the pump. For installations using the
fountain tops directly on the Tee Piece, the
top level of the platform should be 300 mm
(12") below the water level. For installations
using the fountain tops directly on the Tee
Piece and Telescopic Stem , the top level of
the platform should be 450 mm (18") below
the water level.
Fountain Only.
(See Fig 7 for general installation guide)
1. Place the pump next to the pond and
route the cable back to the mains supply.
2. Position the pump with the Tee Piece
Assembly and if required the Telescopic
Stem with the fountain fitted in the
desired position in the pond. The 2 and 3
tier fountain heads simply snap onto the
fountain stem (See Fig 4).
3. The fountain height can be regulated to
suit your needs by rotating the Fountain
Flow Adjuster. See Fig 5 (L).
4. If required, the 2-Tier Fountain head, Fig 5
(M), can be used to achieve an alternative
and higher display pattern than the 3-Tier,
Fig 5 (N)
5. The Bell Fountain creates a decorative
waterbell. The size of the bell can be
regulated by adjusting the flow through
the Tee Piece by rotating the fountain
flow adjuster and or by raising or
lowering the top of the Bell in main Bell
Body.
6. The ball joint on the bottom of the tee
Piece (See Fig 5, O) can be used to adjust
the fountain angle so that it is vertical.
Fountain and Waterfall.
(See Fig 8 for general installation guide)
1. Position the pump as previously described.
2. Attach a suitable length of 25 mm (1")
hose to the Threaded Hose tail, Fig 5 (P),
and secure with a suitable hose clip and
position the outlet end of the hose in the
desired position.
3. Screw the Threaded Hose tail onto the
waterfall outlet side of the Tee Piece.
4. The combination of waterfall and
fountain will reduce the fountain height
that can be achieved.
5. Once the pump is operating the flow of
the waterfall and the height of the
fountain can be independently adjusted.
Waterfall Only.
(See Fig 9 for general installation guide)
1. Position the pump as previously described.
2. Attach a suitable length of 25 mm (1")
hose to the Threaded Hose tail and secure
with a suitable hose clip and position the
outlet end of the hose in the desired
position.
3. For maximum waterfall flow, screw the
Threaded Hose tail directly onto the
outlet of the pump. Some installations
require the flow of the water to be
adjusted. In these cases, screw the Tee
Piece to the outlet of the pump, screw the
Threaded Hose tail to the water fall
outlet boss and adjust the flow using the
waterfall flow adjuster, Fig 5 (Q), to suit
your needs.
MAINTENANCE
The Hozelock Cyprio range of Cascade pumps
have been designed to allow fast and easy
maintenance. As with all pumps of its kind,
occasionally it will become necessary to clean
the Strainer Cage and Fountain Spray head
ring.
ALWAYS UNPLUG OR DISCONNECT ALL
APPLIANCES IN THE POND FROM THE
ELECTRICITY SUPPLY BEFORE PUTTING YOUR
HANDS IN THE WATER OR STARTING
MAINTENANCE.
Fountain Head
1. Place a coin or similar in the slot and
gently lever off the fountain head.
2. Rinse in clean water and reassemble.
Strainer.
1. Remove the accessories from the pump
outlet.
2. Holding the pump in one hand, press the
release button (R) on the top of the pump
and open Strainer Cage. See Fig 5.
3. Slide the pump out of its location and
wash/rinse the Strainer Cage with clean
water. The hinges on the Strainer Cage
should also be washed clean at this time.
4. Reassemble the pump.
Rotor Assembly.
1. Remove the Strainer Cage as described
above.
2. Release the Pump Chamber, Fig 6 (S), by
rotating it until the two retaining tongues
are clear of the lugs on the Motor Body.
3. Gently pull the Pump Chamber squarely
away from the Motor Body.
4. Pull the Rotor Assembly out of the Motor
Body. See Fig 6 (T).
5. Wash out all of the components in clean
water. Do not use detergents or other
chemical cleaners.
6. Replace the Rotor Assembly into the
Motor Body and refit the Pump Chamber
and Strainer Cage.
ALL YEAR PUMP CARE
A quick daily check should be carried out to
ensure that the pump is performing
satisfactorily.