6 INSTALLATION

7KH VWRYH PXVW EH LQVWDOOHG E\ TXDOL¿HG SHUVRQQHO LQ FRPSOLDQFH ZLWK (1 
6.1 LEVELLING THE STOVE
The stove must be levelled by adjusting the feet (where featured), then checked
using a spirit level (Fig. 6.1).
A B = Spirit level
6.2 SYSTEM CONNECTIONS
6.2.1 Electrical connection
The stove is connected to the electrical system simply using the plug supplied.
The electrical connection (plug) must be easily accessible when the stove is installed.
If the power cord is damaged it must be replaced by the technical service or a
TXDOL¿HG WHFKQLFLDQ WR SUHYHQW DQ\ NLQG RI ULVN
6.2.1.1 (DUWK
7KH V\VWHP PXVW EH HDUWKHG DQG ¿WWHG ZLWK D UHVLGXDO FXUUHQW FLUFXLWEUHDNHU LQ
accordance with legislation in force (Fig. 6.2).
7KH ÀXH PXVW KDYH LWV RZQ HDUWK FRQQHFWLRQ
6.2.2 Connection to an external timer thermostat
The stove can be connected to an external timer thermostat that switches the stove
on or off according to the set temperature.
When the set temperature is reached the thermostat opens the circuit and
consequently switches off the stove.
The external thermostat is connected to the two terminals on the rear of the stove,
which are jumpered in the factory. Disconnect the jumper and connect the two
thermostat contacts.
7KH VWRYH PXVW EH VHW WR FRQ¿JXUDWLRQ 1 following the instructions shown in the
SDUDJUDSK RQ ³,QLWLDO FRQ¿JXUDWLRQ´
$IWHU ¿UVW LQVWDOOLQJ WKH WLPHU WKHUPRVWDW WKH VWRYH QHHGV WR EH VZLWFKHG RQ PDQXDOO\
while the timer thermostat is in "call" status. This operation is also required in the
event of power failures or if the stove is switched off manually.
To avoid overlapping the working time bands, it's recommend to disable (set to OFF)
the stove's timer (see par. 10.1).
6.2.3 Operation with room probe
In certain circumstances the stove may need to modulate operation based on the
WHPSHUDWXUH UHDG E\ WKH URRP SUREH ¿WWHG RQ WKH VWRYH
7KH VWRYH PXVW EH VHW WR FRQ¿JXUDWLRQ 2 following the instructions shown in paragraph
6.3.
6.2.4 Connection to a storage tank with coil
7KH VWRYH FDQ EH XVHG WR PDLQWDLQ WKH WHPSHUDWXUH LQVLGH D VWRUDJH WDQN ¿WWHG ZLWK
coil.
In this case simply disconnect the external temperature probe from the stove and
¿W LW LQ WKH SUREH VRFNHW RQ WKH VWRUDJH WDQN
7KH VWRYH PXVW EH VHW WR FRQ¿JXUDWLRQ  IROORZLQJ WKH LQVWUXFWLRQV VKRZQ LQ SDUDJUDSK 
6.2.5 Connection to a storage tank without coil
The stove can be used to maintain the temperature inside a storage tank without
coil.
In this case simply disconnect the external temperature probe from the stove and
¿W LW LQ WKH SUREH VRFNHW RQ WKH VWRUDJH WDQN
7KH VWRYH PXVW EH VHW WR FRQ¿JXUDWLRQ 4 following the instructions shown in paragraph 6.3.
40/136
INSTALLATION
cod. 004772131 - 07/2013 - Royal