BFT PERSEO CBD 230.P SD Instrucciones De Instalación página 16

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 37
POWER TERMINAL BLOCK J5
Terminal
24 Vac
2nd
CH
RX
INPUTS TERMINAL BLOCK J9
Terminal
INPUTS TERMINAL BLOCK
Terminal
EF
+
BAT
SHIELD
ANT
16 -
PERSEO CBD 230.P SD
INSTALLATION MANUAL
OUT24
Output 24V~, 1A MAX
LED (Cover lights)
Self-powered output. 24V~, 100mA max
BZ (Cover buzzer)
Self-powered output. 24V, 100mA max
AUX
Free contact relay output; 500mA max, 24V / Vdc
2nd CH RX
Built-in radio receiver 2nd channel N.O. output, max. 500mA, 24 Vac/Vdc
START
N.O. input that operates the bollard's opening and closing. The command is ignored while opening.
PDM
Programmable input. Use parameters FP, PD and AU for the setting procedure.
OPEN
N.O. input - opening only Connect clocks, daily timers or weekly timers here if wanted.
By keeping this input controlled, the automation performs the opening manoeuvre and will close automatically only
when the input is freed.
CLOSE
N.O. input for closing. It allows the automation to be closed only if the safety devices have not triggered.
FTC
NC safety input (photocell). Enter the programme wanted by programming the FT parameter. It triggers only in the
closing phase; it never triggers in opening.
STOP
N.C. safety input. When it is activated, the automation is immediately stopped. During the pause time, a stop control
eliminates the automatic closing, leaving the bollard open waiting for a command.
FCA
Opening limit switch N.O. input. . When activated the opening travel finishes.
Not used
.
J10
EF Electric brake output
Connection for two white power supply cables for the motor's parking electric brake.
Activation is possible only when the bollard is completely lifted.
BAT Input for anti blackout electric brake feeder.
Permits the continuous power supply of the electric brake even without electrical energy, preventing the bollard
from lowering spontaneously in case of a blackout. Do not connect the batteries directly to this input but request
the original accessory STOPPY BAT.
ANTENNA
Antenna connection for the integrated receiver.
Description
Description
Description

Publicidad

Tabla de contenido
loading

Tabla de contenido