TABLE "B" - LEVEL 2° PROGRAMMING
Parameter
Definition
Default
Request for
Sr
00
maintenance
Programming
maintenance
Nt
00
cycles in
thousands
Programming
maintenance
NL
0.0
cycles in
millions
AV
AUX
00
Te
TERMON
00
Slow-down
Cr
20
speed
INSTALLATION MANUAL
Cross Out
Setting Used
disabled
00
active on the configured outputs
01
active on the configured outputs and the bollard lights flash
02
twice
00-99
0. 0 -9. 9
scheduled maintenance required
00
photocell triggering
01
$ non disponibile
02
PDM contact actuated
03
bollard closed
04
bollard open
05
stop contact actuated
06
warning flash
07
start contact
08
open contact
09
blackout
10
assistance required
11
00-30
10-45
Optional Extras
Description
the request for maintenance is not active.
at the end of the countdown, by means of counters nt
and nL, one of the programmed outputs is activated
(see parameter Av)
at the end of the countdown, by means of counters nt
and nL, one of the programmed outputs is activated
(see parameter Av) and the bollard lights flash twice.
Thanks to the combination of the two parameters
the countdown can be set after which a request for
maintenance is signalled.
Thousands can be set with the nt parameter, millions
with the nL parameter. Example: to set 275,000 main-
tenance manoeuvres set nL on 0.2 and nt on 75. The
value displayed in the parameters updates along with
the manoeuvres.
If the maintenance request is enabled (Sr parameter),
the AUX output is activated once the value set for
parameter nt and nl is reached.
The AUX output is activated if the photocell input is
open, photocell triggered.
The AUX output is activated if the PDM input is closed.
The AUX output is activated when the bollard is closed.
The AUX output is activated when the bollard is open.
The AUX output is activated if the Stop input is open.
The AUX output is activated as described in the Pf
pre-flashing parameter.
The AUX output is activated if the Start input is closed.
The AUX output is activated if the Open input is closed.
The AUX output is activated when the device is
switched on
If configured, the contact indicates that the electronic
control unit has detected an error in the automated de-
vice and, more specifically, has detected that the limit
switches are broken. Whatever the case, the lights on
the top cap triple flash to report the error.
Sets the temperature difference between the bollard's
motor and the ambient temperature in centigrade
degrees.
If the parameter is not zero, the control unit will heat
the motor in order to obtain the set temperature
difference.
Example: TE=15. The control unit will ensure that the
motor maintains a temperature that is 15° above the
ambient temperature.
By setting the parameter FP=3, it is possible to enable
or disable the Termon system, operating directly on the
PDM input.
Sets the deceleration speed at the end of the closing
manoeuvre.
The value of the deceleration speed at the end of
opening is preset by the company.