B: No process water supply
possible cause
No power supply
Shut-off valve in the process
water pipe closed
No water in Stage 3
Pressure pump transports no
water
C: Odour / poor process water quality
possible cause
Incorrect installation
System malfunction
Dry siphon in the drainage pipe
of Stage 3
EN 60
Check
Visual inspection:
-
Room and system
fusing
-
Fusing of the system
circuit board
Function check of the
drinking water feed in
manual operation (see
chapter 6.7.1)
Check the pressure
transmitter
Check whether the pressure
booster system is enabled.
Check
Check of:
"Which water enters the
system?"
Separate ventilation of the
infeed? (e.g. roof
ventilation)
Odour trap to the sewer at
the system drain?
Room ventilation present?
Check of the air pumps (see
chapter 7.4.1)
Check of the electric ball valves
(see chapter 7.3)
Dismantle siphon at overflow of
Stage 3
Operating Manual AquaCycle 2500
Remedies
Determine the cause of the
shut-down!
If necessary, re-insert fuse or
replace the circuit board fuse
Open the shut-off valve
Multiple actuation of the drinking
water feed in manual operation
See the Operating Manual of
your pressure booster system.
Remedy
Introduction only of:
Shower and bath water
Operation only with separate
ventilation, odour trap and room
ventilation
Cleaning and, if necessary,
replacement of the defective
components by Pontos or a
skilled electrician.
Open the cover above the
drainage pipe on top of the
Stage 3 tank and put water into
the discharge pipe until the
siphon is full.