Maintenance; Cleaning And Care; Troubleshooting - Truper PRE-1/6 Manual Del Usuario

Bomba presurizadora
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Maintenance

Cleaning and Care

• Inspect regularly all the mounting screws and double
check they are correctly tightened. If any of the screws is
loose, tighten immediately.

Troubleshooting

Problem
Cause
The pump is not
• The pump is off.
running.
• Problems in the power supply.
• The motor axis is stuck.
The pump is making
• There is air in the system or in the pump.
noise.
The pump does not
• The pump remote selector in is manual
stop when the faucet
mode.
is closed.
• The flow sensor is dirty.
• The valve is closed.
The pump is
• There is air in the pipe or the pump.
functioning but is not
generating pressure.
• The pump is dirty. The flow sensor is blocked
with foreign objects.
If the problems persist despite carrying out the recommended corrective actions,
contact a
Repairs
• Repairs to the equipment shall only be carried out in a
Authorized Service Center
Service and maintenance carried out by non-qualified
persons may be dangerous and could cause personal
injuries and makes the product warranty void.
Solution
• Set the pump automatic selector in automatic
mode (II) or manual (III).
• Check the fuses and power line.
• Remove the purge screw and turn the axis with
a screwdriver.
• Run the pump some minutes with the faucet
opened and discharge air.
• Change to off mode (I) or automatic (II) mode.
• Open the valve.
• Open the valve.
• Run the pump a few minutes with an open
faucet and discharge air.
• Go to a
Center.
Authorized Service Center.
Authorized Service
9
ENGLISH

Hide quick links:

Publicidad

Capítulos

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

14635

Tabla de contenido