BRAIN 03 / BRAIN 04
Guide for the installer
Thank you for choosing our product. GENIUS is sure you will get the performances you expect to satisfy your requirements. All
our products are the result of a many years' experience in the field of the automated systems, strengthened by being part of
a world leading group in this sector.
This 24 V
control unit for swing leaf gates offers high performance and a wide range of adjustments. You get opening and
closing slow-downs, control of one or two motors, a facility for managing opening and closing limit-switches, and the possibility
of managing two TIMECODERS.
A sophisticated electronic control monitors the power circuit at all times and disables the control unit in the event of malfunctions
that could impair efficiency of the electronic clutch.
The parameter settings and the operating logics are shown on a handy LCD display, which indicates gate status during normal
operation. Operating times are controlled by self-learning during programming.
The waterproof enclosure is designed for housing the control unit, the toroidal transformer and any buffer batteries (optional),
and has the characteristics and dimensions indicated in the table below.
Supply voltage of transformer
Supply voltage of control unit
Absorbed power
Motor max. load
Accessories max. load
Flashing lamp/courtesy light max. load
Operating ambient temperature
Protection fuses
Function logics
Opening / closing time
Pause time
Thrust force
Slow-downs
Terminal board inputs
Radio connector
Terminal board outputs
Board dimensions
Characteristics of 230V~ toroidal transformer
Characteristics of 115V~ toroidal transformer
Characteristics of optional batteries
Characteristics of outdoor grade enclosure
Different output values can be obtained on the 24V~ output depending on the mains voltage value. Before start-up,
always check the transformer output voltage. It must not exceed 26V~ for both power feed values of 230V~ and 115V~.
Voltage must be measured load free, i.e. with the transformer powered and disconnected from the board.
To ensure people's safety, all warnings and instructions in this booklet must be carefully observed. Incorrect installation
or incorrect use of the product could cause serious harm to people.
Keep the instructions for future reference
Make sure there is an adequate differential switch upstream of the system as specified by current laws, and install a single-pole
thermal breaker on the electrical power mains.
To lay cables, use adequate rigid and/or flexible tubes.
Always separate connection cables of low voltage accessories from those supplying 115/230 V~. To prevent any interference
whatever, use separate sheaths.
Maximum length of power cables between control unit and motors must never exceed 10 m, using cables of 2.5mm
diameter.
Procedure for securing components inside the water-tight enclosure, refer to paragraph 15.

1. GENERAL CHARACTERISTICS

2. TECHNICAL SPECIFICATIONS

Automatic / Step-by-step automatic/Semi-automatic /
Step-by step semi-automatic/Condominium
Through self-learning during programming
Through self-learning during programming
24 V~ power supply, Supply to batteries, Encoder, Total
opening, Pedestrian opening, Opening safety devices,
Closing safety devices, Stop, Opening travel limit devices,
24V
supply for accessories, 24V
light/ Flashing lamp 24 V , Electrical lock 12 V /~
12V 4Ah dimensions: 90 x 70 x 108 mm.
3. PREPARATIONS
230V~ 50Hz / 115V~ 60Hz (+6 -10%)
24 V~ (+6 -10%) - 50/60 Hz.
3 W
70 W x 2
24V
500mA
24V
15W max.
-20°C +50°C
4 (3 self resetting)
Four levels adjustable on display
At opening and closing
Closing travel limit devices
Rapid 5 pin connector for receiver
for motors, Courtesy
165 x 130 mm.
prim. 230V~ sec. 22V~ 120VA
prim. 115V~ sec. 20V~ 120VA
dimensions: 90 x 70 x 108 mm.
: 90 x 70 x 108 mm.
306 x 225 x 130 mm. - IP55