Kohler K-1188 Guia De Instalacion página 12

Ocultar thumbs Ver también para K-1188:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

9. Test Run the Overflowing Bath
Check all electrical connections, and make sure the electrical power to the unit is turned on.
Make sure union connections to the pump, butterfly valves, and in-line heater are securely hand
tightened. Make sure the bathing well and overflow channel are clean and free of debris.
Position the metal suction screen over the plastic suction cover (see illustration, previous page). The
pump may cavitate if the metal screen is not in place.
Fill the overflowing bath bathing well with water so it overflows the bathing well rim and flows
into the overflow channel. Continue filling the bathing well until both overflow channel sensors are
completely covered with water, and the water level is at the drain overflow.
Verify that the green light in the pump control switch starts to blink automatically within 1/2
minute after the overflow channel sensors are completely submerged.
10. Test the Control Switch
Press the pump control switch to start the pump/motor and begin the hydro-therapy cycle. As the
pump/motor turns on and the water begins to circulate, the light will turn to constant green, and
will stay on as long as the overflowing bath is running.
With the unit running, check all harness (piping) connections for leaks. Visually observe the
cascading water flow over the bathing well rim to verify that it is smooth and even along all four
sides and corners.
If the water is cascading uniformly over all four sides of the bathing well rim, you do not need to
make further leveling adjustments.
If further leveling is necessary, keep the overflowing bath running and turn the adjustable feet up or
down with the 7/8" wrench provided. Make sure the unit is resting on all four adjustable feet.
Verify that the chromatherapy lights (if applicable) are operating. Press the chromatherapy control
switch (located directly across the bath from the power switch) to turn on the lights. Upon start-up
the lights should be changing through the color sequence. Press the light control switch a second
time. The lights should stop sequencing and stay one color. Press the light control switch again and
lights will deactivate.
Check the harness connections for leakage one more time.
Press the pump control switch again to turn off the bath. The green light in the pump control switch
will then start to blink automatically (after approximately 1/2 minute) until the overflowing bath is
drained or restarted.
NOTE: For additional information on operation of your bath, see the "Using Your Overflowing Bath"
section.
1019731-2-C
Overflow Channel
Drain
Overflow
Channel
Sensors
Water
Bathing
Well Rim
12
Control Pad
Control Pad
Kohler Co.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

K-1189

Tabla de contenido