Rough-In Specifications - Bradley WF3203 Manual De Installation

Ocultar thumbs Ver también para WF3203:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

TDB3103, WF3203

Rough-In Specifications

Type A Drain
- Supplies through wall
- Vent through wall off-drain
(mm)
CLEARANCE
HOLE
Figure 2
Type O Drain
- Supplies from above
- |Vented through wall off drain
(mm)
1-1/2" NPT DRAIN
THROUGH WALL
(STUB OUT TO SUIT
TRAP DIMENSIONS)
1" NPT SUPPLIES FROM ABOVE
MUST REDUCE TO 1/2" NOM.
COPPER TUBE ON THESE
CENTERS TO PASS THROUGH
CLEARANCE
HOLE
Figure 3
6
1"
(25)
2"
(51)
2"
(51)
TRAP FOR WALL OUTLET ONLY
4"
(102)
4-3/4"
(121)
DRAIN THROUGH WALL
*17 - 21"
(432 - 533)
*12"
(305)
13" R. TOP ACCESS
1"
(25)
WASHFOUNTAIN
4"
(102)
TRAP FOR WALL OUTLET ONLY
4"
(102)
4-3/4"
(121)
*17 - 21"
DRAIN THROUGH WALL
(432 - 533)
1-26-10
1" NPT COLD SUPPLY THROUGH WALL
1-1/2" NPT DRAIN
36" BOWL
(914)
5" R. BOTTOM ACCESS
1" NPT HOT SUPPLY THROUGH WALL
SUPPLIES THROUGH WALL
Rim Height
TRAP
1-1/2" NPT DRAIN
COLD
7/8"
(22)
7/8"
36" BOWL
(22)
(914)
HOT
7-3/8" R. BOTTOM ACCESS
Bradley Corporation • 215-1332 Rev. U; EN 10-00-002
NOTE:
DRAIN P-TRAP &
SUPPLIES BY OTHERS
NOTE: Supply lines for one to two
washfountains should be 1"; for three
washfountains, 1-1/4". For more than
three washfountains, pipe sizes should
be increased proportionately.
*
ADJUSTMENTS TO VERTICAL DIMENSIONS
FOR VARIOUS RIM HEIGHTS
Application
34"
Adult Height ADA,
(35" WF3203) TAS Adult Height
32"
TAS Ages 11 thru
14 or 15, Grades 6
thru 8 or 9
30"
TAS Ages 4 thru
10 or 11, Grades
Pre-K thru 5 or 6 &
Proposed Juvenile
Height ADA
NOTE: Supply lines for one to two
washfountains should be 1"; for three
washfountains, 1-1/4". For more than
three washfountains, pipe sizes should
be increased proportionately.
Installation
Adjustment
None, as shown
Subtract 2"
Subtract 4"

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Tdb3103