Troubleshooting Support - DURAVIT SensoWash Slim Manual De Instrucciones

Accesorio para el wc con ducha
Ocultar thumbs Ver también para SensoWash Slim:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

propriately labelled containers for disposal of batteries are pro-
vided in shops where batteries are sold and at community
collection points.
Children must not play with plastic bags and packaging material,
due to possible injury or danger of suffocation. Store such mate-
rial safely or dispose of it in an environmentally-friendly manner.
If possible, keep the packaging until the warranty period expires.

9. Troubleshooting support

Recommendation: Initial general action in case of a malfunction
> Disconnect the unit from the mains at the fuse box for at least
3 hours and then reconnect it again.
If your unit does still not work properly after following the
instructions mentioned below, contact help@duravit.com. Have
the article and serial number ready. These can be found on the
nameplate on the back of the operating instructions.
Problem
Indicator lamps and alarm function
The "Status
LED"
on the
B
unit flashes red
once each
3 seconds.
Potential cause
Malfunction.
Solution
> Switch off
SensoWash
.
®
> Switch on
SensoWash
again.
®
If flashing does
not stop:
> Cut off power supply.
> After 30 sec.
connect it again.
EN
Ch.
23

Publicidad

Tabla de contenido
loading

Tabla de contenido