TECHNICAL DATA
Heating//domestic hot water nominal thermal output (Hi)
Heating/domestic hot water nominal thermal power
Heating reduced thermal output (Hi)
Heating reduced thermal power
Domestic hot water reduced thermal output (Hi)
Domestic hot water reduced thermal power
Pn max - Pn min working efficiency
30 % working efficiency
Electric power
Category
Country of destination
Power supply voltage
Protection level
Chimney and skirt losses with burner off
Stop loss
CH operation
Maximum pressure - temperature
Minimum pressure for standard operation
Selection field of CH water temperature
Pump: maximum head available
for system capacity
Membrane expansion tank
Expansion tank pre-charge
DHW operation
Maximum pressure
Minimum pressure
Hot water quantity with ∆t 25°C
with ∆t 30°C
with ∆t 35°C
DHW minimum capacity
Selection field of DHW temperature
Flow regulator
Gas pressure
Methane gas nominal pressure (G 20)
LGP liquid gas nominal pressure (G 30 / G 31)
Hydraulic connections
HC input - output
DHW input-output
Gas input
Boiler dimensions
Height
Width
Depth
Boiler weight
Flow rate (G20)
Air capacity
Flue gas capacity
Mass flow of flue gas (max-min)
Fan performance
Boiler residual head without pipes or flange
Concentric flue gas outlet pipes
Diameter
Maximum length
Losses for a 45°/90° bend
Hole in wall (diameter)
Concentric flue gas outlet pipes
Diameter
Maximum length (without flange)
Losses for a 45°/90° bend
Hole in wall (diameter)
Installation B22P÷B52P
Diameter
Maximum length (without flange)
Separate flue gas outlet pipes
Diameter
Maximum length
Losses for a 45°/90° bend
NOx
Emission values at max. and min. rate of gas G20*
Maximum
CO s.a. lower than
CO2
NOx s.a. lower than
∆t flue gases
Minimum
CO s.a. lower than
CO2
NOx s.a. lower than
∆t flue gases
Multigas table
Lower Wobbe index (at 15°C-1013 mbar)
Lower heat Value
Supply nominal pressure
Supply minimum pressure
Main burner:
11 nozzles
HC maximum gas capacity
DHW maximum gas capacity
HC minimum gas capacity
DHW minimum gas capacity
Maximum pressure downstream CH valve
Maximum pressure downstream DHW valve
Minimum pressure downstream CH valve
Minimum pressure downstream DHW valve
* Check carried out with concentric pipe Ø 60-100 - length 0.85 m - water temperature 80-60°C - flue gas flange of suitable diameter installed
The data expressed must not be used to certificate the system; for certification use the data indicated in the "System handbook" measured during first ignition.
kW
kcal/h
kW
kcal/h
kW
kcal/h
kW
kcal/h
kW
kcal/h
kW
kcal/h
%
%
W
V - Hz
IP
%
W
bar
bar
°C
mbar
l/h
bar
bar
bar
l/min
l/min
l/min
l/min
°C
l/min
mbar
mbar
Ø
Ø
Ø
mm
mm
mm
kg
Nm 3 /h
Nm 3 /h
gr/s
Pa
mm
m
m
mm
mm
m
m
mm
mm
m
mm
m
m
p.p.m.
%
p.p.m.
°C
p.p.m.
%
p.p.m.
°C
Methane gas (G20)
MJ/m 3 S
45.67
MJ/m 3
34.02
mbar (mm H2O)
20 (203.9)
mbar (mm H2O)
13.5 (137.7)
Ø mm
1.35
Sm 3 /h
2.73
kg/h
Sm 3 /h
2.73
kg/h
Sm 3 /h
0.94
kg/h
Sm 3 /h
0.94
kg/h
mbar
11.8
120
mm H2O
mbar
11.8
mm H2O
120
mbar
1.5
mm H2O
15
mbar
1.5
mm H2O
15
l
Butane (G30)
80.58
116.09
28-30 (285.5-305.9)
0.78
2.03
2.03
0.70
0.70
27.8
283
27.8
283
3.3
34
3.3
34
JUNIOR C.S.I.
24 C.S.I.
25.8
22,188
23.9
20,590
8.9
7,654
7.5
6,468
8.9
7,654
7.50
6,468
92.8 - 84.5
91.8
100
II2H3+
-
230-50
X5D
0.15
45
3-90
0.25-0.45
40-80
176
1,000
7
1
8
0.15
13.7
11.4
9.8
2
37-60
10
20
28-30/37
3/4"
1/2"
3/4"
715
405
248
28
39.743
42.330
14.36-15.60
95
60-100
4.25
1/1.5
105
80-125
12.40
1.35/2.2
140
80
25
80
16+16
0.5/0.8
class 3
120
7.3
160
141
160
2.30
100
108
Propane (G31)
70.69
88
37 (377.3)
0.78
2.00
2.00
0.69
0.69
35.8
365
35.8
365
4.3
44
4.3
44
9