Mounting the Faucet
1 . Loosen stem-nut on faucet, remove metal "C" disc
(if attached) .
2 . Attach large diameter 3/8" (red) drain tube to barb fitting
at the faucet base . This tube should be long enough to
reach the drain clamp .
3 . Locate the 1/4" red brine tube that has a preassembled
quick-connect elbow on one end . Connect the open end
to the small barb on the faucet . Make certain that the
tube is not kinked or stressed once the head assembly is
mounted .
4 . Slide chrome plate and black rubber washer onto faucet
by threading both drain tubes through the holes in the
plate and washer .
5 . Slide white extension onto long threaded section of
faucet . Open end of extension should come in contact
with base of faucet .
6 . Slide the washer then the lock washer up threaded
section and thread stem nut on . Do NOT tighten nut at
this time .
7 . Apply three (3) to five (5) wraps of plumbers tape to
faucet stem . Screw quick-connector onto end of threads .
8 . Wet end of blue 3/8" tube . Push into bottom of connector .
for 3/4" . Tug gently to be sure connection is complete .
9 . To remove the tube, push on the fittings' collar and pull
the tube out .
10 . Holding the faucet, feed the three (3) tubes through the
hole in the sink . Position the faucet handle at a
desired location .
11 . Center the faucet and slip "C" disc between the white
extension and the bottom of the counter or sink . Tighten
the stem nut with a wrench until it is tight .
NOTE: Do not overtighten the lock nut. Snug down and
tighten until faucet is secure.
12 . Firmly insert goose-neck spout into faucet base .
14
ROM IV REVERSE OSMOSIS SYSTEM INSTALLATION AND OPERATION GUIDE
4
10
1
7
8
Figure 3
Mounting the System
CAUTION: The filter head assembly should be mounted on a
stud or firm surface. The mounting bracket will
support the weight of the cartridges and help
prevent strain on the water lines.
1 . Select location where unit is to be mounted . The head
assembly is mounted in a vertical position .
2 . When mounting the ROM IV RO System, two (2) screws
are required to mount the head . Measure up from the
floor of the cabinet 15 .5" (39 .4 cm) . See Figure 4 . This
will provide clearance to change the cartridges . The two
(2) screws will be 14" (35 .6) apart and level . Screw the
two (2) screws into the wall . Leave a gap between the
screw head and the wall of 1/8" . The backside of the
system head has two (2) slots that will fit over the screw
heads and slide down to lock .
Figure 4
2
3
Countertop
5
6
12.5" from mounting hole
to bottom of cartridge
2" clearance below cartridges