When using an extension lead, check the minimum cross-sections of the cable:
F
Cable length
NL
up to 20 m
I
20 to 50 m
Operation
N
S
DK
Picking up liquids
SF
Before liquids are picked up, always remove the filter bag.
E
CAUTION – Check that the float works properly.
WARNING – If foam develops or liquid emerges, stop work immediately and empty the dirt tank.
P
Cleaning the filter element
GR
If suction performance drops:
1.
Switching on the vacuum cleaner.
TR
2.
Close the nozzles or suction hose opening with the palm of your hand.
3.
Press the button to start filter cleaning for at least three times for two seconds each. The resulting
SLO
stream of air removes attached dust from the slats of the filter elements.
4.
If the suction power is too low after filter cleaning: replace filter.
HR
Connecting electrical appliances
E
SK
CAUTION! Follow the operating instructions and safety instructions for appliances connected to the
power tool socket.
CZ
Use the socket on the vacuum cleaner for the purpose defined in the operating instructions only.
PL
Before plugging an appliance into the appliance socket:
1.
Switch off the vacuum cleaner.
2.
Switch off the appliance to be connected.
H
+
Maintenance, cleaning and repair
F
G
RO
Only carry out maintenance work described in the operating instructions. Always pull out the mains
plug before cleaning and maintenance of the vacuum cleaner. Never spray water on to the upper sec-
BG
tion of the vacuum cleaner: Danger for persons, risk or short-circuiting.
RUS
The use of non-genuine spare parts and accessories can impair the safety of the appliance. Only use
spare parts and accessories from Makita.
EST
During maintenance and cleaning, handle the vacuum cleaner in such a manner that there is no dan-
ger for maintenance staff or other persons.
LV
In the maintenance area
–
use filtered compulsory ventilation
LT
–
wear protective clothing
–
clean the maintenance are so that no harmful substances get into the surroundings
AL
During maintenance and repair work all contaminated parts that could not be cleaned satisfactorily
must be
MK
–
packed in well sealed bags
–
disposed of in a manner that complies with valid regulations for such waste removal
SR
UK
16
Switch position
I
0
AUTO
Cross section
< 16 A
1,5 mm
2
2,5 mm
2
< 25 A
2,5 mm
2
4,0 mm
2
Function
On