Terminal board connection
Programmer power supply 230 Vac
1-2
Transformer power output 230 Vac
3-4
5
Programmer power supply earth wire
6
Motor earth wire
TB (N.C./8.2 kΩ) stop button input (The opening of this contact
7
interrupts the cycle until a new movement command is given).
CMN common for all inputs and outputs.
8
FS (N.C./8.2 kΩ) safety and control devices in input (stop photo-
9
electric cells). The opening of this contact will block all movement,
until the obstruction has been removed, due to the safety device
cutting in, the gate will then continue moving until it reaches a travel
limit (only in the automatic mode).
10
FI (N.C./8.2 kΩ) safety and control devices in input (photocells invert
the travel direction when an obstruction is detected). Opening this
contact will provoke a travel direction inversion during closure due
to the cutting in of the safety device.
CMN common for all inputs and outputs.
11
CP (N.C./8.2 kΩ) safety buffer input. Opening this contact will
12
provoke a travel direction inversion of 5 cm, a pause of 3 minutes,
after which the motor will continue moving in the original direction
after a 10 second preflashing period has elapsed.
LP 24 Vdc output for warning lights. 25 W intermittent activation
13
(50%), 12,5 W continuous activation.
All rights reserved. Unauthorised copying or use of the information contained in this document is punishable by law
CMN common for all inputs and outputs.
14
24 Vdc output, powering controlled external loads
15
CMN common for all inputs and outputs.
16
24 Vdc output, powering permanent external loads
17
CMN common for all inputs and outputs.
18
TA (NO contact) opening button input.
19
TAL (NO contact) limited opening button input.
20
TC (NO contact) closing button input.
21
TD (NO contact) dynamic button input.
22
CMN Common for all inputs and outputs.
23
LS 24 Vdc, 3W indicator light output.
24
EMRG 1 (NO contact) emergency manoeuvring button input 1
25
EMRG 2 (NO contact) emergency manoeuvring button input 2
26
L1
L
230Vac
N
TRF 230Vac
7
8
9
10
11
12
13
19
20
21
22
23
24
B1
Signal buzzer "via radio" mode
BC
Battery charger card
LCD1 Display
F1
3.1 A rapid fuse (24V battery powered operation protection)
F2
10 A rapid fuse (battery powered operation motor protection)
F3
10 A rapid fuse (motor power protection from transformer)
F4
3.1 A rapid fuse (24V transformer power protection )
(1)
.
(1)
.
10
BC
CTRL
OUT
OUT
24Vdc
24Vdc
14
15
16
17
18
J2
L2
J1
TRANSFORMER
27
Common for both emergency buttons.
28
Outer conductor for the radio receiver antenna
29
Inner conductor for the radio receiver antenna (if an external antenna
is fitted use a coaxial type cable RG58 with an impedance of 50Ω).
Note (
) The total of the 2 external device outputs must not exceed 10W.
1
ALL UNUSED NC CONTACTS MUST BE JUMPED and consequently the
security device test must also be deactivated (FI , FS ).
If you want to activate the FI, FS test both the transmission and receiver
parts of the security devices must be connected to the binding post marked
"CTRL 30 Vdc".
If the test is active there will be a 1 second delay between the command
transmission and movement of the gate.
Switch on the power and make sure that the indicator LEDs are indicating
the following conditions:
- L1
Power on
- L2
Wrong battery connection
- S1 Indicator for the blocking button "TB"
- S2 Indicator for the inverting photoelectric cells "FI"
- S3 Indicator for the stop photoelectric cells "FS"
- S4 Indicator for the safety edge "CP"
- S5 Indicator for the opening button (TA)
- S6 Indicator for the closing button (TC)
- S7 Indicator for the limited opening button (TAL)
- S8 Indicator for the sequential command (TD/CH1)
Note
If this LED is "ON" invert the battery power cables immediately.
(3)
Note
These indications are "ON" if the relative security devices are inactive.
(4)
Check that the activation of the safety devices makes the correspond-
ing indicator lights flash. A fleshing LED indicates an alarm status.
If the green power on LED "L1" doesn't light up check the condition of the
fuses and the power cable connection at the transformer primary.
If one or more of the safety LEDs "S1, S2, S3, S4" flash check the contacts
of the relative security devices and check that the unused safety device
contacts have been bridged.
The indications "S5, S6, S7, S8" appear on the display when the relative
command is activated, eg. pressing the button "TA" will force "TA" to appear
on the display.
R1
B1
M1
M
E1
J1
Battery connection
J2
Transformer secondary connection
J3
Emergency enable jumper
M1
Transmitter code memory module
P1
Menu navigation button (
P2
Programming and confirm button (PROG./OK)
P3
Menu navigation button (
R1
Radio frequency module, 433 MHz for S4XX/S500 transmitters
17
ON
OFF
ON
ON
ON
ON
OFF
OFF
OFF
OFF
CS1412B DC0561
S1
S2
T B
F I
F S
C P
S4
S3
LCD1
P2
P1
PROG/OK
Disable
J3
25 26 27
Enable
)
)
(3)
(4)
(4)
(4)
(4)
P3